Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-12256", "description": "Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets\u2019 IP options.", "id": "GSD-2019-12256" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-12256" ], "details": "Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets\u2019 IP options.", "id": "GSD-2019-12256", "modified": "2023-12-13T01:23:43.863351Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-12256", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets\u2019 IP options." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009", "refsource": "CONFIRM", "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf" }, { "name": "https://security.netapp.com/advisory/ntap-20190802-0001/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20190802-0001/" }, { "name": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/", "refsource": "CONFIRM", "url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2019-12256", "refsource": "CONFIRM", "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2019-12256" }, { "name": "https://support.f5.com/csp/article/K41190253", "refsource": "CONFIRM", "url": "https://support.f5.com/csp/article/K41190253" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.9.4.12", "versionStartIncluding": "6.5", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netapp:e-series_santricity_os_controller:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "8.40.50.00", "versionStartIncluding": "8.00", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.5.4.3", "versionStartIncluding": "6.5.4.0.", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.5.3.3", "versionStartIncluding": "6.5.3.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.5.2.3", "versionStartIncluding": "6.5.2.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.5.1.4", "versionStartIncluding": "6.5.1.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.5.0.3", "versionStartIncluding": "6.5.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.2.7.4", "versionStartIncluding": "6.2.7.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.2.6.1", "versionStartIncluding": "6.2.6.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.2.5.3", "versionStartIncluding": "6.2.5.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.2.4.3", "versionStartIncluding": "6.2.4.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.2.3.1", "versionStartIncluding": "6.2.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.9.1.12", "versionStartIncluding": "5.9.1.0.", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "5.9.0.7", "versionStartIncluding": "5.9.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:6.2.7.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:6.2.7.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:6.2.7.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:sonicwall:sonicos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "6.2.9.2", "versionStartIncluding": "6.2.9.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:siprotec_5_firmware:*:*:*:*:*:*:*:cp200", "cpe_name": [], "versionEndExcluding": "7.59", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:siprotec_5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:siprotec_5_firmware:*:*:*:*:*:*:*:cp300", "cpe_name": [], "versionEndExcluding": "7.91", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:siprotec_5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:power_meter_9410_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.2.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:power_meter_9410:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:power_meter_9810_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:power_meter_9810:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_win7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "bs5.2.461.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_win7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_win7018_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "bs5.2.461.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_win7018:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_win7025_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "bs5.2.461.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_win7025:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_win7200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "bs5.2.461.17", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_win7200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "07.0.07", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rail_switch_power_lite:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rail_switch_power_smart:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_red25:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_grs1042:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_grs1142:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_grs1020:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_grs1120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_grs1030:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_grs1130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_eesx20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_eesx30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_ees20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_ees25:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_msp30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_msp32:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rspe30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rspe32:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rspe35:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rspe37:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rsp25:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rsp30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rsp35:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_rsp20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "07.5.01", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_octopus_os3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_msp40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "07.2.04", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_dragon_mach4000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_dragon_mach4500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:belden:hirschmann_hios:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "05.3.06", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_eagle20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_eagle30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:belden:hirschmann_eagle_one:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:belden:garrettcom_magnum_dx940e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.0.1_y7", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:belden:garrettcom_magnum_dx940e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-12256" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets\u2019 IP options." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-120" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-632562.pdf" }, { "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2019-0009" }, { "name": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2019-12256", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://support2.windriver.com/index.php?page=cve\u0026on=view\u0026id=CVE-2019-12256" }, { "name": "https://support2.windriver.com/index.php?page=security-notices", "refsource": "MISC", "tags": [ "Issue Tracking", "Vendor Advisory" ], "url": "https://support2.windriver.com/index.php?page=security-notices" }, { "name": "https://security.netapp.com/advisory/ntap-20190802-0001/", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20190802-0001/" }, { "name": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://www.windriver.com/security/announcements/tcp-ip-network-stack-ipnet-urgent11/" }, { "name": "https://support.f5.com/csp/article/K41190253", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://support.f5.com/csp/article/K41190253" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-189842.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352504.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2022-08-16T13:00Z", "publishedDate": "2019-08-09T18:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.