gsd-2019-10923
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7, SIMATIC S7-400 CPU 414F-3 PN/DP V7, SIMATIC S7-400 CPU 416-3 PN/DP V7, SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2019-10923",
    "description": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions \u003c V4.1.1 Patch 05), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions \u003c V4.5.0 Patch 01), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions \u003c V4.5.0), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.1), SIMATIC ET200M (incl. SIPLUS variants) (All versions), SIMATIC ET200S (incl. SIPLUS variants) (All versions), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 (6ES7141-6BH00-0AB0) (All versions), SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 (6ES7142-6BH00-0AB0) (All versions), SIMATIC ET200ecoPN, 4AO U/I 4xM12 (6ES7145-6HD00-0AB0) (All versions), SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 (6ES7147-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 (6ES7142-6BR00-0AB0) (All versions), SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 (6ES7144-6KD50-0AB0) (All versions), SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 (6ES7144-6KD00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 (6ES7141-6BF00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 (6ES7141-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 (6ES7142-6BF50-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 (6ES7142-6BF00-0AB0) (All versions), SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 (6ES7142-6BG00-0AB0) (All versions), SIMATIC ET200ecoPN: IO-Link Master (6ES7148-6JA00-0AB0) (All versions), SIMATIC ET200pro (All versions), SIMATIC NET CP 1604 (All versions \u003c V2.8), SIMATIC NET CP 1616 (All versions \u003c V2.8), SIMATIC PN/PN Coupler 6ES7158-3AD01-0XA0 (incl. SIPLUS NET variant) (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions \u003c SIMATIC WinAC RTX 2010 SP3), SIMOTION (incl. SIPLUS variants) (All versions), SINAMICS DCM (All versions \u003c V1.5 HF1), SINAMICS DCP (All versions \u003c V1.3), SINAMICS G110M V4.7 Control Unit (All versions \u003c V4.7 SP10 HF5), SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) (All versions \u003c V4.7 SP10 HF5), SINAMICS G130 V4.7 Control Unit (All versions \u003c V4.7 HF29), SINAMICS G150 Control Unit (All versions \u003c V4.8), SINAMICS GH150 V4.7 Control Unit (All versions), SINAMICS GL150 V4.7 Control Unit (All versions), SINAMICS GM150 V4.7 Control Unit (All versions), SINAMICS S110 Control Unit (All versions), SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) (All versions \u003c V4.7 HF34), SINAMICS S150 Control Unit (All versions \u003c V4.8), SINAMICS SL150 V4.7 Control Unit (All versions \u003c V4.7 HF33), SINAMICS SM120 V4.7 Control Unit (All versions), SINUMERIK 828D (All versions \u003c V4.8 SP5), SINUMERIK 840D sl (All versions). An attacker with network access to an affected product may cause a Denial-of-Service condition by breaking the real-time synchronization (IRT) of the affected installation. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts the availability of the affected installations.",
    "id": "GSD-2019-10923"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2019-10923"
      ],
      "details": "A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN/DP V7,  SIMATIC S7-400 CPU 414F-3 PN/DP V7,  SIMATIC S7-400 CPU 416-3 PN/DP V7,  SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.",
      "id": "GSD-2019-10923",
      "modified": "2023-12-13T01:23:58.349344Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "productcert@siemens.com",
        "ID": "CVE-2019-10923",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": " SIMATIC S7-400 CPU 414-3 PN/DP V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": " SIMATIC S7-400 CPU 414F-3 PN/DP V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": " SIMATIC S7-400 CPU 416-3 PN/DP V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": " SIMATIC S7-400 CPU 416F-3 PN/DP V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.1.1 Patch 05"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.5.0 Patch 01"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.5.0"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V5.2.1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET 200S IM151-8 PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET 200S IM151-8F PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200ecoPN: IO-Link Master",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200M (incl. SIPLUS variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200pro",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC ET200S (incl. SIPLUS variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC NET CP 1604",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V2.8"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC NET CP 1616",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V2.8"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 314C-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.3.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 315-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 315F-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 315T-3 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 317-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 317F-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 317T-3 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 319-3 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-300 CPU 319F-3 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-400 CPU 412-2 PN V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinAC RTX 2010",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V2010 SP3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMATIC WinAC RTX F 2010",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V2010 SP3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIMOTION",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS DCM",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V1.5 HF1"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS DCP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V1.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS G110M V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.7 SP10 HF5"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.7 SP10 HF5"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS G130 V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.7 HF29"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS G150 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.8"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS GH150 V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS GL150 V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS GM150 V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS S110 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.7 HF34"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS S150 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.8"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS SL150 V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.7 HF33"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINAMICS SM120 V4.7 Control Unit",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINUMERIK 828D",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.8 SP5"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SINUMERIK 840D sl",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V4.8 SP5"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS ET 200S IM151-8 PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS ET 200S IM151-8F PN/DP CPU",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-300 CPU 314C-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.3.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-300 CPU 315-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-300 CPU 315F-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-300 CPU 317-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-300 CPU 317F-2 PN/DP",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V3.2.17"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All versions \u003c V7.0.3"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Siemens"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN/DP V7,  SIMATIC S7-400 CPU 414F-3 PN/DP V7,  SIMATIC S7-400 CPU 416-3 PN/DP V7,  SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-400",
                "lang": "eng",
                "value": "CWE-400: Uncontrolled Resource Consumption"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf",
            "refsource": "MISC",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.1",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:p4:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5.0",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_firmware:4.5.0:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.3.17",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2010",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp1:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:sp2:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.5",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.8",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "4.8",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10923"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in  SIMATIC S7-400 CPU 414-3 PN/DP V7,  SIMATIC S7-400 CPU 414F-3 PN/DP V7,  SIMATIC S7-400 CPU 416-3 PN/DP V7,  SIMATIC S7-400 CPU 416F-3 PN/DP V7, Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SCALANCE X-200IRT switch family (incl. SIPLUS NET variants), SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200M (incl. SIPLUS variants), SIMATIC ET200pro, SIMATIC ET200S (incl. SIPLUS variants), SIMATIC NET CP 1604, SIMATIC NET CP 1616, SIMATIC PN/PN Coupler (incl. SIPLUS NET variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 CPU 412-2 PN V7, SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants), SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SIMOTION, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4.7 Control Unit, SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4.7 Control Unit, SINAMICS GL150 V4.7 Control Unit, SINAMICS GM150 V4.7 Control Unit, SINAMICS S110 Control Unit, SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants), SINAMICS S150 Control Unit, SINAMICS SL150 V4.7 Control Unit, SINAMICS SM120 V4.7 Control Unit, SINUMERIK 828D, SINUMERIK 840D sl, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP, SIPLUS S7-400 CPU 414-3 PN/DP V7, SIPLUS S7-400 CPU 416-3 PN/DP V7. An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-349422.pdf"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 10.0,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 3.6
        }
      },
      "lastModifiedDate": "2023-05-09T13:15Z",
      "publishedDate": "2019-10-10T14:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.