** DISPUTED ** Vivotek FD8136 devices allow Remote Command Injection, aka "another command injection vulnerability in our target device," a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it's performance.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2018-14495",
    "description": "** DISPUTED ** Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance.",
    "id": "GSD-2018-14495"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2018-14495"
      ],
      "details": "** DISPUTED ** Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance.",
      "id": "GSD-2018-14495",
      "modified": "2023-12-13T01:22:38.110835Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2018-14495",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "** DISPUTED ** Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/",
            "refsource": "MISC",
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "name": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/",
            "refsource": "MISC",
            "url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vivotek:fd8136_firmware:0301a:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BB045BEF-F482-4B29-8966-E1CA77FD9F71",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vivotek:fd8136:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "23008BB5-E0BD-482E-BB65-419C009847A8",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "Vivotek FD8136 devices allow Remote Command Injection, aka \"another command injection vulnerability in our target device,\" a different issue than CVE-2018-14494. NOTE: The vendor has disputed this as a vulnerability and states that the issue does not cause a web server crash or have any other affect on it\u0027s performance"
          },
          {
            "lang": "es",
            "value": "** EN DISPUTA ** Los dispositivos FD8136 de Vivotek, permiten la inyecci\u00f3n de comandos remota, tambi\u00e9n se conoce como \"another command injection vulnerability in our target device\", un problema diferente de CVE-2018-14494. NOTA: El fabricante ha disputado esto como una vulnerabilidad y declara que no causa un bloqueo del servidor web ni tiene ning\u00fan otro efecto en su rendimiento."
          }
        ],
        "id": "CVE-2018-14495",
        "lastModified": "2024-04-11T01:00:40.947",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2019-07-10T14:15:10.637",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.vdalabs.com/2018/07/23/professional-iot-hacking-series-target-selection-firmware-analysis/"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.vdalabs.com/2018/08/06/professional-iot-hacking-series-hunting-remote-command-injection/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…