GSD-2018-12981

Vulnerability from gsd - Updated: 2023-12-13 01:22
Details
An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability can be exploited by authenticated and unauthenticated users by sending special crafted requests to the web server allowing injecting code within the WBM. The code will be rendered and/or executed in the browser of the user's browser.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2018-12981",
    "description": "An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability can be exploited by authenticated and unauthenticated users by sending special crafted requests to the web server allowing injecting code within the WBM. The code will be rendered and/or executed in the browser of the user\u0027s browser.",
    "id": "GSD-2018-12981",
    "references": [
      "https://packetstormsecurity.com/files/cve/CVE-2018-12981"
    ]
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2018-12981"
      ],
      "details": "An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability can be exploited by authenticated and unauthenticated users by sending special crafted requests to the web server allowing injecting code within the WBM. The code will be rendered and/or executed in the browser of the user\u0027s browser.",
      "id": "GSD-2018-12981",
      "modified": "2023-12-13T01:22:29.846259Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cve@mitre.org",
        "ID": "CVE-2018-12981",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability can be exploited by authenticated and unauthenticated users by sending special crafted requests to the web server allowing injecting code within the WBM. The code will be rendered and/or executed in the browser of the user\u0027s browser."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert.vde.com/en-us/advisories/vde-2018-010",
            "refsource": "MISC",
            "url": "https://cert.vde.com/en-us/advisories/vde-2018-010"
          },
          {
            "name": "https://www.sec-consult.com/en/blog/advisories/remote-code-execution-via-multiple-attack-vectors-in-wago-edisplay/",
            "refsource": "MISC",
            "url": "https://www.sec-consult.com/en/blog/advisories/remote-code-execution-via-multiple-attack-vectors-in-wago-edisplay/"
          },
          {
            "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-02",
            "refsource": "MISC",
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-02"
          },
          {
            "name": "https://www.wago.com/medias/SA-WBM-2018-004.pdf?context=bWFzdGVyfHJvb3R8MjgyNzYwfGFwcGxpY2F0aW9uL3BkZnxoMWUvaDg4LzkzNjE3NTIxOTUxMDIucGRmfDU1NmJkYjEzNDY0ZGU4OWQ1OTMyMjUwNTlmZTI0MzgwNDQ1MDY1YzU3OWRmZDk1NzYzODAwMDI3ODg1NDJlZjU",
            "refsource": "CONFIRM",
            "url": "https://www.wago.com/medias/SA-WBM-2018-004.pdf?context=bWFzdGVyfHJvb3R8MjgyNzYwfGFwcGxpY2F0aW9uL3BkZnxoMWUvaDg4LzkzNjE3NTIxOTUxMDIucGRmfDU1NmJkYjEzNDY0ZGU4OWQ1OTMyMjUwNTlmZTI0MzgwNDQ1MDY1YzU3OWRmZDk1NzYzODAwMDI3ODg1NDJlZjU"
          },
          {
            "name": "45014",
            "refsource": "EXPLOIT-DB",
            "url": "https://www.exploit-db.com/exploits/45014/"
          },
          {
            "name": "20180711 SEC Consult SA-20180711-0 :: Remote code execution via multiple attack vectors in WAGO e!DISPLAY 7300T",
            "refsource": "FULLDISC",
            "url": "http://seclists.org/fulldisclosure/2018/Jul/38"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:762-3000_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "02",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:762-3000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:762-3001_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "02",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:762-3001:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:762-3002_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "02",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:762-3002:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:762-3003_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "02",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:762-3003:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-12981"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "An issue was discovered on WAGO e!DISPLAY 762-3000 through 762-3003 devices with firmware before FW 02. The vulnerability can be exploited by authenticated and unauthenticated users by sending special crafted requests to the web server allowing injecting code within the WBM. The code will be rendered and/or executed in the browser of the user\u0027s browser."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.wago.com/medias/SA-WBM-2018-004.pdf?context=bWFzdGVyfHJvb3R8MjgyNzYwfGFwcGxpY2F0aW9uL3BkZnxoMWUvaDg4LzkzNjE3NTIxOTUxMDIucGRmfDU1NmJkYjEzNDY0ZGU4OWQ1OTMyMjUwNTlmZTI0MzgwNDQ1MDY1YzU3OWRmZDk1NzYzODAwMDI3ODg1NDJlZjU",
              "refsource": "CONFIRM",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://www.wago.com/medias/SA-WBM-2018-004.pdf?context=bWFzdGVyfHJvb3R8MjgyNzYwfGFwcGxpY2F0aW9uL3BkZnxoMWUvaDg4LzkzNjE3NTIxOTUxMDIucGRmfDU1NmJkYjEzNDY0ZGU4OWQ1OTMyMjUwNTlmZTI0MzgwNDQ1MDY1YzU3OWRmZDk1NzYzODAwMDI3ODg1NDJlZjU"
            },
            {
              "name": "https://www.sec-consult.com/en/blog/advisories/remote-code-execution-via-multiple-attack-vectors-in-wago-edisplay/",
              "refsource": "MISC",
              "tags": [
                "Exploit",
                "Third Party Advisory"
              ],
              "url": "https://www.sec-consult.com/en/blog/advisories/remote-code-execution-via-multiple-attack-vectors-in-wago-edisplay/"
            },
            {
              "name": "https://cert.vde.com/en-us/advisories/vde-2018-010",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2018-010"
            },
            {
              "name": "20180711 SEC Consult SA-20180711-0 :: Remote code execution via multiple attack vectors in WAGO e!DISPLAY 7300T",
              "refsource": "FULLDISC",
              "tags": [
                "Exploit",
                "Mailing List",
                "Third Party Advisory"
              ],
              "url": "http://seclists.org/fulldisclosure/2018/Jul/38"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-02",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-198-02"
            },
            {
              "name": "45014",
              "refsource": "EXPLOIT-DB",
              "tags": [
                "Exploit",
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "https://www.exploit-db.com/exploits/45014/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "confidentialityImpact": "NONE",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          "exploitabilityScore": 6.8,
          "impactScore": 2.9,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "LOW",
          "userInteractionRequired": true
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 2.3,
          "impactScore": 2.7
        }
      },
      "lastModifiedDate": "2021-05-20T20:09Z",
      "publishedDate": "2018-07-12T18:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…