GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2013-0662

Vulnerability from gsd - Updated: 2023-12-13 01:22
Details
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2013-0662",
    "description": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.",
    "id": "GSD-2013-0662",
    "references": [
      "https://packetstormsecurity.com/files/cve/CVE-2013-0662"
    ]
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2013-0662"
      ],
      "details": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.",
      "id": "GSD-2013-0662",
      "modified": "2023-12-13T01:22:14.702666Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2013-0662",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "n/a",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "n/a"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "n/a"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "n/a"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01",
            "refsource": "CONFIRM",
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
          },
          {
            "name": "45219",
            "refsource": "EXPLOIT-DB",
            "url": "https://www.exploit-db.com/exploits/45219/"
          },
          {
            "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01",
            "refsource": "MISC",
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
          },
          {
            "name": "66500",
            "refsource": "BID",
            "url": "http://www.securityfocus.com/bid/66500"
          },
          {
            "name": "45220",
            "refsource": "EXPLOIT-DB",
            "url": "https://www.exploit-db.com/exploits/45220/"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:concept:*:sr7:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.6",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:modbus_serial_driver:1.10:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:modbus_serial_driver:2.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:modbus_serial_driver:3.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:modbuscommdtm_sl:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.1.2",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:opc_factory_server:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "3.5.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:opc_factory_server:3.34:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:opc_factory_server:3.35:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:pl7:*:sp7:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "4.5",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:powersuite:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.6",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:sft2841:13.1:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:sft2841:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "14.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:somachine:2.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:somachine:3.0:-:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:somachine:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "3.1",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "1.7",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:twidosuite:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.31.04",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:unity_pro:6.0:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:unity_pro:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "7.0",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:unityloader:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.3",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:schneider_electric:somachine:3.0:*:*:*:xs:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0662"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01",
              "refsource": "MISC",
              "tags": [
                "Mitigation",
                "Third Party Advisory",
                "US Government Resource"
              ],
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01"
            },
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01",
              "refsource": "CONFIRM",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01"
            },
            {
              "name": "66500",
              "refsource": "BID",
              "tags": [
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "http://www.securityfocus.com/bid/66500"
            },
            {
              "name": "45220",
              "refsource": "EXPLOIT-DB",
              "tags": [
                "Exploit",
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "https://www.exploit-db.com/exploits/45220/"
            },
            {
              "name": "45219",
              "refsource": "EXPLOIT-DB",
              "tags": [
                "Exploit",
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "https://www.exploit-db.com/exploits/45219/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.6,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        }
      },
      "lastModifiedDate": "2022-02-03T13:57Z",
      "publishedDate": "2014-04-01T06:17Z"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…