Action not permitted
Modal body text goes here.
ghsa-cxc2-v3v8-ggcp
Vulnerability from github
Published
2022-07-12 00:00
Modified
2022-07-12 00:00
Severity ?
Details
In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.
{ "affected": [], "aliases": [ "CVE-2022-30791" ], "database_specific": { "cwe_ids": [ "CWE-400" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-07-11T11:15:00Z", "severity": "MODERATE" }, "details": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected.", "id": "GHSA-cxc2-v3v8-ggcp", "modified": "2022-07-12T00:00:57Z", "published": "2022-07-12T00:00:57Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-30791" }, { "type": "WEB", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "type": "CVSS_V3" } ] }
cve-2022-30791
Vulnerability from cvelistv5
Published
2022-07-11 10:40
Modified
2024-09-16 16:48
Severity ?
EPSS score ?
Summary
CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T07:03:38.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CODESYS Control RTE (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control RTE (for Beckhoff CX) SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Win (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Gateway", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Windows", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS HMI (SL)", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Development System V3", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.10", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control Runtime System Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Embedded Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Remote Target Visu Toolkit", "vendor": "CODESYS", "versions": [ { "lessThan": "V3.5.18.20", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for BeagleBone SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Beckhoff CX9020 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for emPC-A/iMX6 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for IOT2000 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Linux SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC100 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PFC200 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for PLCnext SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for Raspberry Pi SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Control for WAGO Touch Panels 600 SL", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "product": "CODESYS Edge Gateway for Linux", "vendor": "CODESYS", "versions": [ { "lessThan": "V4.5.0.0", "status": "affected", "version": "V3", "versionType": "custom" } ] } ], "datePublic": "2022-07-08T00:00:00", "descriptions": [ { "lang": "en", "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400 Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-07-11T10:40:38", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ], "source": { "defect": [ "CERT@VDE#", "64129" ], "discovery": "UNKNOWN" }, "title": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-07-08T06:00:00.000Z", "ID": "CVE-2022-30791", "STATE": "PUBLIC", "TITLE": "CODESYS V3: CmpBlkDrvTcp allows unauthenticated attackers to block all its available TCP connections" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Gateway", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Edge Gateway for Windows", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Development System V3", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.10" } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Embedded Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Remote Target Visu Toolkit", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V3.5.18.20" } ] } }, { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Beckhoff CX9020 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } }, { "product_name": "CODESYS Edge Gateway for Linux", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "V3", "version_value": "V4.5.0.0" } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400 Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=", "refsource": "CONFIRM", "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17128\u0026token=bee4d8a57f19be289d623ec90135493b5f9179e3\u0026download=" } ] }, "source": { "defect": [ "CERT@VDE#", "64129" ], "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2022-30791", "datePublished": "2022-07-11T10:40:38.913416Z", "dateReserved": "2022-05-16T00:00:00", "dateUpdated": "2024-09-16T16:48:31.565Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.