ghsa-c3ch-5j34-5m4f
Vulnerability from github
Published
2022-05-17 04:30
Modified
2022-05-17 04:30
VLAI Severity ?
Details
CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded application password, which makes it easier for remote authenticated users to obtain application-file access via unspecified vectors.
{
"affected": [],
"aliases": [
"CVE-2014-5420"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2014-10-19T01:55:00Z",
"severity": "LOW"
},
"details": "CareFusion Pyxis SupplyStation 8.1 with hardware test tool before 1.0.16 has a hardcoded application password, which makes it easier for remote authenticated users to obtain application-file access via unspecified vectors.",
"id": "GHSA-c3ch-5j34-5m4f",
"modified": "2022-05-17T04:30:26Z",
"published": "2022-05-17T04:30:26Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2014-5420"
},
{
"type": "WEB",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-288-01"
}
],
"schema_version": "1.4.0",
"severity": []
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…