fkie_cve-2025-53520
Vulnerability from fkie_nvd
Published
2025-08-08 17:15
Modified
2025-08-08 20:30
Summary
The affected product allows firmware updates to be downloaded from EG4's website, transferred via USB dongles, or installed through EG4's Monitoring Center (remote, cloud-connected interface) or via a serial connection, and can install these files without integrity checks. The TTComp archive format used for the firmware is unencrypted and can be unpacked and altered without detection.
Impacted products
Vendor Product Version



{
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The affected product allows firmware updates to be downloaded from EG4\u0027s\n website, transferred via USB dongles, or installed through EG4\u0027s \nMonitoring Center (remote, cloud-connected interface) or via a serial \nconnection, and can install these files without integrity checks. The \nTTComp archive format used for the firmware is unencrypted and can be \nunpacked and altered without detection."
    },
    {
      "lang": "es",
      "value": "El producto afectado permite descargar actualizaciones de firmware desde el sitio web de EG4, transferirlas mediante llaves USB o instalarlas a trav\u00e9s de EG4\u0027s Monitoring Center (interfaz remota conectada a la nube) o mediante una conexi\u00f3n serial, y puede instalar estos archivos sin comprobaciones de integridad. El formato de archivo TTComp utilizado para el firmware no est\u00e1 cifrado y puede descomprimirse y modificarse sin ser detectado."
    }
  ],
  "id": "CVE-2025-53520",
  "lastModified": "2025-08-08T20:30:18.180",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.6,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "ACTIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-08-08T17:15:29.507",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://eg4electronics.com/contact/"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-07"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-494"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…