fkie_cve-2025-24004
Vulnerability from fkie_nvd
Published
2025-07-08 07:15
Modified
2025-07-11 14:36
Severity ?
Summary
A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog.
References
▼ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://certvde.com/de/advisories/VDE-2025-014 | Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:charx_sec-3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6338C05A-3F0E-408E-98B1-51B2EAE05F5B", "versionEndIncluding": "1.6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:charx_sec-3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D1095269-9D5A-4557-BA9D-33B49AAA339F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:charx_sec-3050_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC6EA57F-57E6-437F-8035-3B714A4E824C", "versionEndIncluding": "1.6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:charx_sec-3050:-:*:*:*:*:*:*:*", "matchCriteriaId": "775BA5ED-968B-4759-BA39-50F9EAB29169", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:charx_sec-3100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "160F031E-81BB-466B-808D-6BF46D28BD17", "versionEndIncluding": "1.6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:charx_sec-3100:-:*:*:*:*:*:*:*", "matchCriteriaId": "F498BFB3-3C39-4F0B-9775-0B4F891D866C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:phoenixcontact:charx_sec-3150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B0E8722-3BCD-4360-BF23-7BC020A28D51", "versionEndIncluding": "1.6.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:phoenixcontact:charx_sec-3150:-:*:*:*:*:*:*:*", "matchCriteriaId": "32916BED-0241-4787-960C-7A4E8E1DDED7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog." }, { "lang": "es", "value": "Un atacante f\u00edsico con acceso a la pantalla del dispositivo a trav\u00e9s de USB-C puede enviar un mensaje al dispositivo que activa una copia no segura a un b\u00fafer, lo que genera una p\u00e9rdida de integridad y una denegaci\u00f3n de servicio temporal para las estaciones hasta que sean reiniciadas por el organismo de control." } ], "id": "CVE-2025-24004", "lastModified": "2025-07-11T14:36:09.917", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "LOW", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 4.2, "source": "info@cert.vde.com", "type": "Primary" } ] }, "published": "2025-07-08T07:15:24.127", "references": [ { "source": "info@cert.vde.com", "tags": [ "Third Party Advisory" ], "url": "https://certvde.com/de/advisories/VDE-2025-014" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "info@cert.vde.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…