fkie_cve-2025-12996
Vulnerability from fkie_nvd
Published
2025-12-04 20:16
Modified
2025-12-22 18:09
Severity ?
4.1 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N
4.1 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N
4.1 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N
Summary
Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| medtronic | carelink_network | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:medtronic:carelink_network:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F732E0FA-C285-4923-873F-3080AC1032F8",
"versionEndExcluding": "2025-12-04",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under certain circumstances. This issue affects CareLink Network: before December 4, 2025."
}
],
"id": "CVE-2025-12996",
"lastModified": "2025-12-22T18:09:56.777",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.5,
"impactScore": 3.6,
"source": "security@medtronic.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.5,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2025-12-04T20:16:17.340",
"references": [
{
"source": "security@medtronic.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.medtronic.com/en-us/e/product-security/security-bulletins/carelink-network-vulnerabilities.html"
}
],
"sourceIdentifier": "security@medtronic.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "security@medtronic.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…