FKIE_CVE-2024-6207

Vulnerability from fkie_nvd - Published: 2024-10-14 21:15 - Updated: 2026-06-17 08:17
Summary
CVE 2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html  and send a specially crafted CIP message to the device. If exploited, a threat actor could help prevent access to the legitimate user and end connections to connected devices including the workstation. To recover the controllers, a download is required which ends any process that the controller is running.
Impacted products
Vendor Product Version
rockwellautomation controllogix_5580_firmware *
rockwellautomation controllogix_5580_firmware *
rockwellautomation controllogix_5580_firmware *
rockwellautomation controllogix_5580 -
rockwellautomation controllogix_5580_process_firmware *
rockwellautomation controllogix_5580_process_firmware *
rockwellautomation controllogix_5580_process_firmware *
rockwellautomation controllogix_5580_process -
rockwellautomation guardlogix_5580_firmware *
rockwellautomation guardlogix_5580_firmware *
rockwellautomation guardlogix_5580_firmware *
rockwellautomation guardlogix_5580 -
rockwellautomation compactlogix_5380_firmware *
rockwellautomation compactlogix_5380_firmware *
rockwellautomation compactlogix_5380_firmware *
rockwellautomation compactlogix_5380 -
rockwellautomation compact_guardlogix_5380_sil_2_firmware *
rockwellautomation compact_guardlogix_5380_sil_2_firmware *
rockwellautomation compact_guardlogix_5380_sil_2_firmware *
rockwellautomation compact_guardlogix_5380_sil_2 -
rockwellautomation compact_guardlogix_5380_sil_3_firmware *
rockwellautomation compact_guardlogix_5380_sil_3_firmware *
rockwellautomation compact_guardlogix_5380_sil_3_firmware *
rockwellautomation compact_guardlogix_5380_sil_3 -
rockwellautomation compactlogix_5480_firmware *
rockwellautomation compactlogix_5480_firmware *
rockwellautomation compactlogix_5480_firmware *
rockwellautomation compactlogix_5480 -
rockwellautomation factorytalk_logix_echo_firmware *
rockwellautomation factorytalk_logix_echo_firmware *
rockwellautomation factorytalk_logix_echo -

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V28.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5580 Process",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V33.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V31.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5380",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V28.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380 SIL 2",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V31.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380 SIL 3",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V32.013"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5480",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V32.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae Logix Echo",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V33.011"
            }
          ]
        }
      ],
      "source": "PSIRT@rockwellautomation.com"
    },
    {
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
            "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "compactlogix_5380_firmware",
          "vendor": "rockwellautomation",
          "versions": [
            {
              "lessThan": "33.017",
              "status": "affected",
              "version": "28.011",
              "versionType": "custom"
            },
            {
              "lessThan": "34.014",
              "status": "affected",
              "version": "34.0",
              "versionType": "custom"
            },
            {
              "lessThan": "35.013",
              "status": "affected",
              "version": "35.0",
              "versionType": "custom"
            },
            {
              "lessThan": "36.011",
              "status": "affected",
              "version": "36.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "controllogix_5580_process_firmware",
          "vendor": "rockwellautomation",
          "versions": [
            {
              "lessThan": "33.017",
              "status": "affected",
              "version": "33.011",
              "versionType": "custom"
            },
            {
              "lessThan": "34.014",
              "status": "affected",
              "version": "34.0",
              "versionType": "custom"
            },
            {
              "lessThan": "35.013",
              "status": "affected",
              "version": "35.0",
              "versionType": "custom"
            },
            {
              "lessThan": "36.011",
              "status": "affected",
              "version": "36.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil2_firmware:*:*:*:*:*:*:*:*",
            "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "guardlogix_5580_firmware",
          "vendor": "rockwellautomation",
          "versions": [
            {
              "lessThan": "33.017",
              "status": "affected",
              "version": "31.011",
              "versionType": "custom"
            },
            {
              "lessThan": "34.014",
              "status": "affected",
              "version": "34.0",
              "versionType": "custom"
            },
            {
              "lessThan": "35.013",
              "status": "affected",
              "version": "35.0",
              "versionType": "custom"
            },
            {
              "lessThan": "36.011",
              "status": "affected",
              "version": "36.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "controllogix_5580_process_firmware",
          "vendor": "rockwellautomation",
          "versions": [
            {
              "lessThan": "33.017",
              "status": "affected",
              "version": "32.011",
              "versionType": "custom"
            },
            {
              "lessThan": "34.014",
              "status": "affected",
              "version": "34.0",
              "versionType": "custom"
            },
            {
              "lessThan": "35.013",
              "status": "affected",
              "version": "35.0",
              "versionType": "custom"
            },
            {
              "lessThan": "36.011",
              "status": "affected",
              "version": "36.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil3_firmware:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "compact_guardlogix_5380_sil3_firmware",
          "vendor": "rockwellautomation",
          "versions": [
            {
              "lessThan": "33.017",
              "status": "affected",
              "version": "32.013",
              "versionType": "custom"
            },
            {
              "lessThan": "34.014",
              "status": "affected",
              "version": "34.0",
              "versionType": "custom"
            },
            {
              "lessThan": "35.013",
              "status": "affected",
              "version": "35.0",
              "versionType": "custom"
            },
            {
              "lessThan": "36.011",
              "status": "affected",
              "version": "36.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:rockwellautomation:factorytalk_logix_echo:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "factorytalk_logix_echo",
          "vendor": "rockwellautomation",
          "versions": [
            {
              "lessThan": "34.014",
              "status": "affected",
              "version": "33.011",
              "versionType": "custom"
            },
            {
              "lessThan": "35.013",
              "status": "affected",
              "version": "35.0",
              "versionType": "custom"
            },
            {
              "lessThan": "36.011",
              "status": "affected",
              "version": "36.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CCECB24-3DF9-441D-B2E0-7EDD305EA31D",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "28.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "999BE839-8688-4723-A067-788386E528D7",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D70BDEA5-B19E-4399-AD46-FA94285B2DEA",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8EF3D88-B9BC-4FEA-BA35-8657EEE463F2",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "33.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A3A96A6-242A-4022-8347-E04467DA6FDA",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D377807-09D3-4430-8B0D-83BB5514B275",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580_process:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFEDADD8-01DE-4AE5-A0D7-532347FA7DB2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF92BE9B-AF7A-4A04-9438-C30C5ED49B07",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "31.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0E0F65D-98D1-4021-9CB0-402834F46DD8",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "956AF3D2-9A47-4BAD-B3A5-37A8965DBB2E",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C85E19A-8153-4AC2-8A15-DD1CEE9F5B2E",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "28.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "90519681-C70B-49EE-A551-29D5A9EFCA31",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A306250-9B1A-49A4-B6C1-E2EFBA49504B",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93D9D75D-0C98-408B-9EB1-6315AAE1147B",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "31.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58CAFC2B-2C95-41E0-BB00-7E7F89103664",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37997377-0939-4D3C-8A97-F4F8C6FB1000",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E594CDF6-0582-4D5C-B6AA-C8A2E752E29F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D85D8A23-BC23-41F9-A17A-33239D4C90B5",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "32.013",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13C157F1-BD62-4F6A-8DCF-4660983C9948",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A01F13C3-42C1-409C-A16E-6BEC723108A2",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B82D842C-0930-41AA-83CD-5F235771AE4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A890317E-B6BD-4A0A-B7E0-E50D90506EF1",
              "versionEndExcluding": "33.017",
              "versionStartIncluding": "32.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "881D835B-D7E3-44C5-9B77-CA82EDCE2D3C",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "34.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0ABD910-7EBE-44C8-97E3-2B523CDEE5FA",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:rockwellautomation:factorytalk_logix_echo_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02105DF7-661C-47E7-BC52-771356537783",
              "versionEndExcluding": "34.014",
              "versionStartIncluding": "33.011",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:rockwellautomation:factorytalk_logix_echo_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "51ECB73D-C08C-4DE1-BA75-608E9C350751",
              "versionEndExcluding": "35.013",
              "versionStartIncluding": "35.011",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:rockwellautomation:factorytalk_logix_echo:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7898895B-17A1-499A-9B09-9F6C1C302368",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CVE 2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html \u00a0and send a specially crafted CIP message to the device.  If exploited, a threat actor could help prevent access to the legitimate user and end connections to connected devices including the workstation.  To recover the controllers, a download is required which ends any process that the controller is running."
    },
    {
      "lang": "es",
      "value": "CVE 2021-22681 https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.PN1550.html y enviar un mensaje CIP especialmente manipulado al dispositivo. Si se explota, un actor de amenazas podr\u00eda ayudar a evitar el acceso al usuario leg\u00edtimo y finalizar las conexiones a los dispositivos conectados, incluida la estaci\u00f3n de trabajo. Para recuperar los controladores, se requiere una descarga que finalice cualquier proceso que est\u00e9 ejecutando el controlador."
    }
  ],
  "id": "CVE-2024-6207",
  "lastModified": "2026-06-17T08:17:30.737",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "PSIRT@rockwellautomation.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "PSIRT@rockwellautomation.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-6207",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2024-10-15T14:11:41.281080Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2024-10-14T21:15:12.460",
  "references": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1707.html"
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "PSIRT@rockwellautomation.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…