fkie_cve-2024-5990
Vulnerability from fkie_nvd
Published
2024-06-25 16:15
Modified
2024-11-21 09:48
Summary
Due to an improper input validation, an unauthenticated threat actor can send a malicious message to a monitor thread within Rockwell Automation ThinServer™ and cause a denial-of-service condition on the affected device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BC59B57-F8F5-4979-826B-EAA0A8456B2A",
              "versionEndExcluding": "11.1.8",
              "versionStartIncluding": "11.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79481998-C98B-4486-A2DC-C4DE324DCA10",
              "versionEndExcluding": "11.2.9",
              "versionStartIncluding": "11.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD553E2-EB04-4D97-AD70-2175933E3DCD",
              "versionEndExcluding": "12.0.7",
              "versionStartIncluding": "12.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC5BBCD2-0C47-4B48-81DD-D56D5677BFA0",
              "versionEndExcluding": "12.1.8",
              "versionStartIncluding": "12.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "74B76C09-5C22-4D58-85AC-D9D643F3AB73",
              "versionEndExcluding": "13.0.4",
              "versionStartIncluding": "13.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinmanager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2789DF38-D501-415B-8D62-D3B7324B977E",
              "versionEndExcluding": "13.1.2",
              "versionStartIncluding": "13.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33A7D7B2-945B-48AD-AD65-C1DDD52811DC",
              "versionEndExcluding": "11.1.8",
              "versionStartIncluding": "11.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "808EDF9D-E721-4513-8AC9-A7B86163F0AE",
              "versionEndExcluding": "11.2.9",
              "versionStartIncluding": "11.2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D00E4B0-2B55-460B-B394-BE0E379144FA",
              "versionEndExcluding": "12.0.7",
              "versionStartIncluding": "12.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D2E6604-AED5-4099-B2EB-E33F15095C6A",
              "versionEndExcluding": "12.1.8",
              "versionStartIncluding": "12.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F115CDD-5656-4133-8976-69C9DE85CED3",
              "versionEndExcluding": "13.0.4",
              "versionStartIncluding": "13.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:rockwellautomation:thinserver:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AED71D3B-5B11-48D7-9886-BA221CAB0F14",
              "versionEndExcluding": "13.1.2",
              "versionStartIncluding": "13.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Due to an improper input validation, an unauthenticated threat actor can send a malicious message to a monitor thread within Rockwell Automation ThinServer\u2122 and cause a denial-of-service condition on the affected device."
    },
    {
      "lang": "es",
      "value": "Debido a una validaci\u00f3n de entrada incorrecta, un actor de amenazas no autenticado puede enviar un mensaje malicioso a un hilo de monitor dentro de Rockwell Automation ThinServer\u2122 y provocar una condici\u00f3n de denegaci\u00f3n de servicio en el dispositivo afectado."
    }
  ],
  "id": "CVE-2024-5990",
  "lastModified": "2024-11-21T09:48:42.467",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "PSIRT@rockwellautomation.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-06-25T16:15:25.470",
  "references": [
    {
      "source": "PSIRT@rockwellautomation.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1677.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1677.html"
    }
  ],
  "sourceIdentifier": "PSIRT@rockwellautomation.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "PSIRT@rockwellautomation.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…