fkie_cve-2024-57684
Vulnerability from fkie_nvd
Published
2025-01-16 19:15
Modified
2025-05-02 19:31
Severity ?
Summary
An access control issue in the component formDMZ.cgi of D-Link 816A2_FWv1.10CNB05_R1B011D88210 allows unauthenticated attackers to set the DMZ service of the device via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dlink | dir-816_firmware | 1.10cnb05_r1b011d88210 | |
| dlink | dir-816 | a2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dlink:dir-816_firmware:1.10cnb05_r1b011d88210:*:*:*:*:*:*:*",
"matchCriteriaId": "6494A725-3860-4428-A0F3-076605CAF7F2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dlink:dir-816:a2:*:*:*:*:*:*:*",
"matchCriteriaId": "1A3AC507-7219-401E-AC60-12D96382E4B7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in the component formDMZ.cgi of D-Link 816A2_FWv1.10CNB05_R1B011D88210 allows unauthenticated attackers to set the DMZ service of the device via a crafted POST request."
},
{
"lang": "es",
"value": " Un problema de control de acceso en el componente formDMZ.cgi de D-Link 816A2_FWv1.10CNB05_R1B011D88210 permite a atacantes no autenticados configurar el servicio DMZ del dispositivo a trav\u00e9s de una solicitud POST manipulada."
}
],
"id": "CVE-2024-57684",
"lastModified": "2025-05-02T19:31:55.613",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-16T19:15:29.700",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Unauthorized_Vulnerability/D-Link/DIR-816/formDMZ.md"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.dlink.com/en/security-bulletin/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-276"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…