fkie_cve-2024-4872
Vulnerability from fkie_nvd
Published
2024-08-27 13:15
Modified
2024-10-30 15:31
Severity ?
9.9 (Critical) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability
an attacker must have a valid credential.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hitachienergy | microscada_pro_sys600 | 9.4 | |
| hitachienergy | microscada_pro_sys600 | 9.4 | |
| hitachienergy | microscada_pro_sys600 | 9.4 | |
| hitachienergy | microscada_pro_sys600 | 9.4 | |
| hitachienergy | microscada_pro_sys600 | 9.4 | |
| hitachienergy | microscada_x_sys600 | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf1:*:*:*:*:*:*",
"matchCriteriaId": "0B90ED6E-68E4-4C14-B275-F44BAC1B9C5C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf2:*:*:*:*:*:*",
"matchCriteriaId": "196E08EA-807C-4B7B-981A-96D106AC328B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf3:*:*:*:*:*:*",
"matchCriteriaId": "680FAE83-9D7A-4AD9-AFBE-480FD105ADC9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf4:*:*:*:*:*:*",
"matchCriteriaId": "014C8428-8F88-4C3D-B9B1-87DE26867471",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.4:fixpack_2_hf5:*:*:*:*:*:*",
"matchCriteriaId": "06AFA271-0785-4526-B7DA-FA00672CC5B5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AEAAFA90-ACFF-47E2-A23D-728912D74B99",
"versionEndExcluding": "10.6",
"versionStartIncluding": "10.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability\nan attacker must have a valid credential."
},
{
"lang": "es",
"value": "El producto no valida ninguna consulta sobre datos persistentes, lo que genera riesgo de ataques de inyecci\u00f3n."
}
],
"id": "CVE-2024-4872",
"lastModified": "2024-10-30T15:31:41.743",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.1,
"impactScore": 6.0,
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-08-27T13:15:05.890",
"references": [
{
"source": "cybersecurity@hitachienergy.com",
"tags": [
"Vendor Advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-943"
}
],
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…