fkie_cve-2024-4245
Vulnerability from fkie_nvd
Published
2024-04-27 08:15
Modified
2025-01-27 18:28
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md | Broken Link | |
| cna@vuldb.com | https://vuldb.com/?ctiid.262136 | Permissions Required, Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.262136 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?submit.319830 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md | Broken Link | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.262136 | Permissions Required, Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.262136 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.319830 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | i21_firmware | 1.0.0.14\(4656\) | |
| tenda | i21 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:i21_firmware:1.0.0.14\\(4656\\):*:*:*:*:*:*:*",
"matchCriteriaId": "2A8E6370-3A83-4813-A1D8-A106DB130DCB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECC76541-E312-4C4E-A906-C41951FADAD9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad fue encontrada en Tenda i21 1.0.0.14(4656) y clasificada como cr\u00edtica. La funci\u00f3n formQosManageDouble_user es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento ssidIndex provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El identificador de esta vulnerabilidad es VDB-262136. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2024-4245",
"lastModified": "2025-01-27T18:28:31.410",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-04-27T08:15:06.277",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.262136"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.262136"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.319830"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.262136"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.262136"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.319830"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…