fkie_cve-2024-23784
Vulnerability from fkie_nvd
Published
2024-02-14 10:15
Modified
2025-03-25 17:15
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected product.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| sharp | jh-rvb1_firmware | * | |
| sharp | jh-rvb1 | * | |
| sharp | jh-rv11_firmware | * | |
| sharp | jh-rv11 | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sharp:jh-rvb1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B7EC16DF-21FB-473F-8F62-DDBF1C149A9B",
"versionEndIncluding": "b0.1.9.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sharp:jh-rvb1:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AE2814EB-D067-4920-A450-4F90431EA461",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sharp:jh-rv11_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E0A2340C-A0BC-4DD5-A120-F7041D76D776",
"versionEndIncluding": "b0.1.9.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sharp:jh-rv11:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F6906-8ED6-40DE-8B18-260B7765C4A9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper access control vulnerability exists in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier, which may allow a network-adjacent unauthenticated attacker to obtain a username and its hashed password displayed on the management page of the affected product."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de control de acceso inadecuado en Energy Management Controller con servicios en la nube JH-RVB1 /JH-RV11 Ver.B0.1.9.1 y anteriores, lo que puede permitir a un atacante no autenticado adyacente a la red obtener un nombre de usuario y su contrase\u00f1a hash que se muestran en la p\u00e1gina de administraci\u00f3n del producto afectado."
}
],
"id": "CVE-2024-23784",
"lastModified": "2025-03-25T17:15:50.533",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-02-14T10:15:08.610",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU94591337/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU94591337/"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…