fkie_cve-2024-20154
Vulnerability from fkie_nvd
Published
2025-01-06 04:15
Modified
2025-01-06 15:15
Severity ?
Summary
In Modem, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00720348; Issue ID: MSV-2392.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In Modem, there is a possible out of bounds write due to a missing bounds check. This could lead to remote code execution, if a UE has connected to a rogue base station controlled by the attacker, with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY00720348; Issue ID: MSV-2392."
},
{
"lang": "es",
"value": "En Modem, existe la posibilidad de una escritura fuera de los l\u00edmites debido a la falta de una verificaci\u00f3n de los l\u00edmites. Esto podr\u00eda provocar la ejecuci\u00f3n remota de c\u00f3digo, si un UE se ha conectado a una estaci\u00f3n base no autorizada controlada por el atacante, sin necesidad de privilegios de ejecuci\u00f3n adicionales. No se necesita la interacci\u00f3n del usuario para la explotaci\u00f3n. ID de parche: MOLY00720348; ID de problema: MSV-2392."
}
],
"id": "CVE-2024-20154",
"lastModified": "2025-01-06T15:15:13.343",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-01-06T04:15:07.770",
"references": [
{
"source": "security@mediatek.com",
"url": "https://corp.mediatek.com/product-security-bulletin/January-2025"
}
],
"sourceIdentifier": "security@mediatek.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "security@mediatek.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…