A command execution vulnerability exists in the tddpd enable_test_mode functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926 and Tp-Link N300 Wireless Access Point (EAP115 V4) v5.0.4 Build 20220216. A specially crafted series of network requests can lead to arbitrary command execution. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.This vulnerability impacts `uclited` on the EAP115(V4) 5.0.4 Build 20220216 of the N300 Wireless Gigabit Access Point.
Impacted products
Vendor Product Version
tp-link eap225_firmware 5.1.0
tp-link eap225 v3
tp-link eap115_firmware 5.0.4
tp-link eap115 v4



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tp-link:eap225_firmware:5.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "15CAB41B-D47A-42E1-AEFB-9E342492E231",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tp-link:eap225:v3:*:*:*:*:*:*:*",
              "matchCriteriaId": "07736B46-7E3D-4E45-A554-440470FEE33B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tp-link:eap115_firmware:5.0.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FF9ABB5-A353-4491-B928-50C0843D9597",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tp-link:eap115:v4:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E0DB1CB-D156-4AE2-A815-B653A7D797FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A command execution vulnerability exists in the tddpd enable_test_mode functionality of Tp-Link AC1350 Wireless MU-MIMO Gigabit Access Point (EAP225 V3) v5.1.0 Build 20220926 and Tp-Link N300 Wireless Access Point (EAP115 V4) v5.0.4 Build 20220216. A specially crafted series of network requests can lead to arbitrary command execution. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.This vulnerability impacts `uclited` on the EAP115(V4) 5.0.4 Build 20220216 of the N300 Wireless Gigabit Access Point."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad de ejecuci\u00f3n de comando en la funcionalidad tddpd enable_test_mode del punto de acceso Gigabit MU-MIMO inal\u00e1mbrico Tp-Link AC1350 (EAP225 V3) v5.1.0 compilaci\u00f3n 20220926 y el punto de acceso inal\u00e1mbrico Tp-Link N300 (EAP115 V4) v5.0.4 compilaci\u00f3n 20220216. Una serie de solicitudes de red especialmente manipuladas pueden conducir a la ejecuci\u00f3n de comandos arbitrarios. Un atacante puede enviar una secuencia de paquetes no autenticados para desencadenar esta vulnerabilidad. Esta vulnerabilidad afecta a \"uclited\" en el EAP115(V4) 5.0.4 Build 20220216 del punto de acceso Gigabit inal\u00e1mbrico N300."
    }
  ],
  "id": "CVE-2023-49134",
  "lastModified": "2025-11-04T19:16:09.063",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-09T15:15:29.220",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1862"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2023-1862"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2023-1862"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-829"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…

Loading…