fkie_cve-2023-47542
Vulnerability from fkie_nvd
Published
2024-04-09 15:15
Modified
2025-01-17 17:11
Severity ?
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
A improper neutralization of special elements used in a template engine [CWE-1336] in FortiManager versions 7.4.1 and below, versions 7.2.4 and below, and 7.0.10 and below allows attacker to execute unauthorized code or commands via specially crafted templates.
References
| URL | Tags | ||
|---|---|---|---|
| psirt@fortinet.com | https://fortiguard.com/psirt/FG-IR-23-419 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://fortiguard.com/psirt/FG-IR-23-419 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| fortinet | fortimanager | * | |
| fortinet | fortimanager | * | |
| fortinet | fortimanager | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B1EF673-5967-401E-98E3-B7A2B1BEF037",
"versionEndExcluding": "7.0.11",
"versionStartIncluding": "7.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4763E504-6974-42C5-B912-3E62A9CC312A",
"versionEndExcluding": "7.2.5",
"versionStartIncluding": "7.2.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "83316FAF-C5DE-4603-B3B2-6796E2FAF1A8",
"versionEndExcluding": "7.4.2",
"versionStartIncluding": "7.4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A improper neutralization of special elements used in a template engine [CWE-1336] in FortiManager versions 7.4.1 and below, versions 7.2.4 and below, and 7.0.10 and below allows attacker to execute unauthorized code or commands via specially crafted templates."
},
{
"lang": "es",
"value": "Una neutralizaci\u00f3n inadecuada de elementos especiales utilizados en un motor de plantillas [CWE-1336] en FortiManager versiones 7.4.1 e inferiores, versiones 7.2.4 e inferiores, y 7.0.10 e inferiores permite al atacante ejecutar c\u00f3digo o comandos no autorizados a trav\u00e9s de plantillas especialmente manipuladas."
}
],
"id": "CVE-2023-47542",
"lastModified": "2025-01-17T17:11:28.947",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "psirt@fortinet.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-04-09T15:15:28.207",
"references": [
{
"source": "psirt@fortinet.com",
"tags": [
"Vendor Advisory"
],
"url": "https://fortiguard.com/psirt/FG-IR-23-419"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://fortiguard.com/psirt/FG-IR-23-419"
}
],
"sourceIdentifier": "psirt@fortinet.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1336"
}
],
"source": "psirt@fortinet.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-94"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…