fkie_cve-2023-29413
Vulnerability from fkie_nvd
Published
2023-04-18 21:15
Modified
2024-11-21 07:57
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296", "versionEndIncluding": "2.5-ga-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B", "versionEndIncluding": "2.5-gs-01-22320", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*", "matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*", "matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*", "matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*", "matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968", "vulnerable": false }, { "criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*", "matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n" } ], "id": "CVE-2023-29413", "lastModified": "2024-11-21T07:57:00.790", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cybersecurity@se.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-04-18T21:15:09.523", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…