fkie_cve-2023-29413
Vulnerability from fkie_nvd
Published
2023-04-18 21:15
Modified
2024-11-21 07:57
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause
Denial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor
service.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:apc_easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D52617D6-0503-4B6B-A59D-441E0D1F4296",
"versionEndIncluding": "2.5-ga-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1849E03C-445A-4225-AECD-B4A7502F5F3B",
"versionEndIncluding": "2.5-gs-01-22320",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:microsoft:windows_10:-:*:*:*:*:*:*:*",
"matchCriteriaId": "21540673-614A-4D40-8BD7-3F07723803B0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_11:-:*:*:*:*:*:-:*",
"matchCriteriaId": "647F2145-B063-43EA-8045-32D3B4D893F6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DB79EE26-FC32-417D-A49C-A1A63165A968",
"vulnerable": false
},
{
"criteria": "cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "821614DD-37DD-44E2-A8A4-FE8D23A33C3C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nA CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause\nDenial-of-Service when accessed by an unauthenticated user on the Schneider UPS Monitor\nservice. \n\n \n\n\n\n"
}
],
"id": "CVE-2023-29413",
"lastModified": "2024-11-21T07:57:00.790",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-04-18T21:15:09.523",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-101-04.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…