FKIE_CVE-2023-1968

Vulnerability from fkie_nvd - Published: 2023-04-28 19:15 - Updated: 2026-06-17 05:29
Summary
Instruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications.

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "iScan Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.0"
            },
            {
              "status": "affected",
              "version": "4.0.5"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiniSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "2.0 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "iSeq 100",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 (RUO Mode)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MiSeqDx Operating Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0.1 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 500/550 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 550Dx Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "4.0 (RUO Mode)"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 550Dx Operating Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.3.1",
              "status": "affected",
              "version": "1.0.0 ",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "1.3.3 "
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NextSeq 1000/2000 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NovaSeq 6000 Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "lessThanOrEqual": "1.7 ",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "NovaSeq Control Software",
          "vendor": "Illumina ",
          "versions": [
            {
              "status": "affected",
              "version": "1.8"
            }
          ]
        }
      ],
      "source": "ics-cert@hq.dhs.gov"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:iscan_firmware:4.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5000279-D40B-4526-B911-9E0641736EE1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:illumina:iscan_firmware:4.0.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD7BE281-02B5-4B87-A7E2-D0E3BB5309CF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:iscan:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08732A94-734B-486E-AB2C-A2E2CA3C66AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:iseq_100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D22304CE-8F36-4B51-BAA2-E2C564C04CDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:iseq_100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0136ED72-BF05-404D-910A-DA5B73F69771",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:miniseq_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4B7C1F7-D185-4C72-B23C-A21103267CD6",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:miniseq:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DA69772-E795-4A64-A6A1-0BDD503D263B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:miseq_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC028805-6ED3-455B-8F4C-95A8B8C5E756",
              "versionStartIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:miseq:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8AFB0D5A-AF5A-4A84-963F-C6307ADCFF4E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:miseqdx_firmware:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "E97A49E3-4B87-4FE5-8FD4-5B36C61A0650",
              "versionStartIncluding": "4.0.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:illumina:miseqdx_firmware:4.0:*:*:*:ruo:*:*:*",
              "matchCriteriaId": "BE1CBD4E-42B1-42C6-9B3F-4F715A5DBF6D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:miseqdx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD56D9E-B16C-4ED4-A2E4-E73A3A9A599B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_500_firmware:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "22E34BB5-591C-4889-851E-9A66212C8B8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:nextseq_500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C7AEA5A-707D-4BF4-9DF6-BDE6E6D97B60",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_550_firmware:4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0D02B5D-7E8A-41CD-BE27-5B012BE5C016",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:nextseq_550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF742B4D-0FC5-443A-8040-7B0A1B298707",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_550dx_firmware:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "93DC004D-271D-4075-9828-E88CD7FFC403",
              "versionEndIncluding": "1.3.1",
              "versionStartIncluding": "1.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_550dx_firmware:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "E199B789-BF31-40AC-B15E-31A97257002B",
              "versionStartIncluding": "1.3.3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_550dx_firmware:4.0:*:*:*:ruo:*:*:*",
              "matchCriteriaId": "78D581A6-38A5-4F0A-A5CB-B25A9337EE78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:nextseq_550dx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3D5AB9D-7EAA-45F2-A10F-A2D142B20D3D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_1000_firmware:1.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "94B82675-AA38-4584-82BD-9C376F80EA49",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:nextseq_1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93589C3C-F577-4C67-962F-166E28911ED2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:nextseq_2000_firmware:1.4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6671E6F8-85D5-4970-98FE-6189C8F98852",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:nextseq_2000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "753D8FDF-5D25-46B9-8E66-30FB8E8A9A87",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:illumina:novaseq_6000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A429D26-AF22-4AC2-AB02-76C72B9B9B05",
              "versionEndIncluding": "1.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:illumina:novaseq_6000_firmware:1.8:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4C702B1-4BAD-4E32-9659-D9F5C3F2F922",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:illumina:novaseq_6000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D879686-89E7-4152-AEF9-DC8A33FDA4A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "\nInstruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications. \n\n\n\n\n\n\n\n"
    }
  ],
  "id": "CVE-2023-1968",
  "lastModified": "2026-06-17T05:29:09.677",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-1968",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-01-16T20:58:25.534437Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2023-04-28T19:15:16.647",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.illumina.com/downloads/illumina-universal-copy-service-1-0.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-117-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1327"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…