FKIE_CVE-2022-24030

Vulnerability from fkie_nvd - Published: 2022-02-03 02:15 - Updated: 2026-08-11 13:17

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "source": "cve@mitre.org"
    },
    {
      "affectedData": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM APE1808 - BIOS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.202N",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Field PG M5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V22.01.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Field PG M6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V26.01.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC127E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V27.01.09",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC227G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC277G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC\u00a0IPC277G PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC327G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC377G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC427E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC477E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC477E PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC627E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC647E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC677E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC847E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ITP1000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V23.01.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS IPC427E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A64DE17F-735B-490B-A4AD-8606684DDB5D",
              "versionEndExcluding": "5.08.41",
              "versionStartIncluding": "5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EE9D6D0-77EF-41CE-ACB2-A43B0543F9C7",
              "versionEndExcluding": "5.16.41",
              "versionStartIncluding": "5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADDAD8E2-7468-4D96-8A9F-8C2BB0E8EACB",
              "versionEndExcluding": "5.26.41",
              "versionStartIncluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AF0CD01-CD57-41D5-9827-437F0683E13B",
              "versionEndExcluding": "5.35.41",
              "versionStartIncluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DA61A73-A290-493E-A797-1A7E7AF0BDE5",
              "versionEndExcluding": "5.43.41",
              "versionStartIncluding": "5.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CB4ED22-F39A-45BD-B748-5C67D0BEEF53",
              "versionEndExcluding": "5.51.41",
              "versionStartIncluding": "5.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en AhciBusDxe en InsydeH2O con el kernel versi\u00f3n 5.1 hasta la versi\u00f3n 5.5. Una vulnerabilidad de corrupci\u00f3n de memoria en SMM permite a un atacante escribir datos fijos o predecibles en SMRAM. La explotaci\u00f3n de este problema podr\u00eda llevar a escalar privilegios a SMM"
    }
  ],
  "id": "CVE-2022-24030",
  "lastModified": "2026-08-11T13:17:24.273",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-03T02:15:07.667",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2022011"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2022011"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.kb.cert.org/vuls/id/796611"
    },
    {
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…