Summary
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
References
| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04 | Patch, Vendor Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "64C0D5C8-3559-4591-8F88-A9D6E3DFA9E4",
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7B2FBBD-C461-47EF-A912-E445C063DED9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD308EE6-41C3-4D93-A2A5-9D7EFF3A8413",
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EAF53585-8B87-4609-991E-30B56B601DEA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "89174639-40D3-4A31-8357-7C497BCF2895",
"versionEndIncluding": "2.6.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC947F97-7E49-475F-84E6-29D7A6DF50CB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
},
{
"lang": "es",
"value": "Una CWE-307: Se presenta una vulnerabilidad de Restricci\u00f3n Inapropiada de los Intentos de Autenticaci\u00f3n Excesivos que podr\u00eda permitir a un atacante manipular al administrador tras numerosos intentos de adivinar las credenciales. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (versiones V2.6.2 y anteriores)"
}
],
"id": "CVE-2022-22810",
"lastModified": "2024-11-21T06:47:29.497",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-02-09T23:15:19.340",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-307"
}
],
"source": "cybersecurity@se.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…