A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
References
URL | Tags | ||
---|---|---|---|
cybersecurity@se.com | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07 | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07 | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
schneider-electric | ecostruxure_power_monitoring_expert | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*", "matchCriteriaId": "F3E7251E-B20A-40A4-9CAD-CD757E2B1450", "versionEndIncluding": "2020", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)" }, { "lang": "es", "value": "Una CWE-79: Se presenta una vulnerabilidad de Neutralizaci\u00f3n Inapropiada de la Entrada Durante la Generaci\u00f3n de la P\u00e1gina Web (\"Cross-site Scripting\") que podr\u00eda permitir a un atacante autenticado visualizar datos, cambiar la configuraci\u00f3n o afectar a la disponibilidad del software cuando el usuario visita una p\u00e1gina que contiene la carga \u00fatil inyectada. Producto afectado: EcoStruxure Power Monitoring Expert (Versiones 2020 y anteriores)" } ], "id": "CVE-2022-22804", "lastModified": "2024-11-21T06:47:28.693", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-04T23:15:13.347", "references": [ { "source": "cybersecurity@se.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07" } ], "sourceIdentifier": "cybersecurity@se.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "cybersecurity@se.com", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…