Summary
An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Impacted products
Vendor Product Version
insyde insydeh2o *
insyde insydeh2o *
insyde insydeh2o *

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "source": "cve@mitre.org"
    },
    {
      "affectedData": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM APE1808 - BIOS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.202N",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Field PG M5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V22.01.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Field PG M6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V26.01.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC127E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V27.01.09",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC227G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC277G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC\u00a0IPC277G PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC327G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC377G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V28.01.04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC427E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC477E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC477E PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC627E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC647E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC677E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC847E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V25.02.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ITP1000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V23.01.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS IPC427E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V21.01.17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "782E4B3F-E5F2-418F-A499-7767030FABAD",
              "versionEndExcluding": "5.14.34",
              "versionStartIncluding": "5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "96AAE5DC-7312-4693-A9EC-8C20D5C0F15C",
              "versionEndExcluding": "5.24.34",
              "versionStartIncluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "27775AD6-E924-4599-9224-5B4E2236642E",
              "versionEndExcluding": "5.24.34",
              "versionStartIncluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en StorageSecurityCommandDxe en InsydeH2O con Kernel versi\u00f3n 5.1 antes de 05.14.28, Kernel versi\u00f3n 5.2 antes de 05.24.28 y Kernel versi\u00f3n 5.3 antes de 05.32.25. Una vulnerabilidad de llamada SMM permite a un atacante secuestrar el flujo de ejecuci\u00f3n del c\u00f3digo que se ejecuta en el modo de gesti\u00f3n del sistema. La explotaci\u00f3n de este problema podr\u00eda conducir a la escalada de privilegios al SMM"
    }
  ],
  "id": "CVE-2021-42113",
  "lastModified": "2026-08-11T13:17:21.560",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.5,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-03T02:15:07.337",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2022008"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2022008"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.kb.cert.org/vuls/id/796611"
    },
    {
      "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…