FKIE_CVE-2021-37185

Vulnerability from fkie_nvd - Published: 2022-02-09 16:15 - Updated: 2026-06-17 04:00
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5. 2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar paquetes especialmente preparados a trav\u00e9s del puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal"
    }
  ],
  "id": "CVE-2021-37185",
  "lastModified": "2026-06-17T04:00:12.923",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2021-37185",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-04-18T15:12:41.029825Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2022-02-09T16:15:12.823",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-672"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…