fkie_cve-2019-6832
Vulnerability from fkie_nvd
Published
2019-09-17 20:15
Modified
2024-11-21 04:47
Severity ?
Summary
A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | wiser_for_knx_firmware | * | |
| schneider-electric | lss100100 | - | |
| schneider-electric | spacelynk_firmware | * | |
| schneider-electric | lss100200 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D4F3391F-8C1E-4A9D-B132-54A5B8CE6D20",
"versionEndExcluding": "2.4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:lss100100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "08F4CDA1-427C-4EF3-B9BE-0DD8CBA81A2D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "101D3290-C8D8-43A7-A50B-B38EA90073FC",
"versionEndExcluding": "2.4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:lss100200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "94DF1B52-1609-4985-B670-BC6AE5675E19",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication."
},
{
"lang": "es",
"value": "A CWE-287: Se presenta vulnerabilidad de Autenticaci\u00f3n en spaceLYnk (todas las versiones anteriores a 2.4.0) y Wiser for KNX (todas las versiones anteriores a 2.4.0 - anteriormente conocido como homeLYnk), lo que podr\u00eda causar la p\u00e9rdida de control cuando un atacante omite la autenticaci\u00f3n."
}
],
"id": "CVE-2019-6832",
"lastModified": "2024-11-21T04:47:14.493",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.5,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-17T20:15:12.407",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…