fkie_cve-2019-6831
Vulnerability from fkie_nvd
Published
2019-09-17 20:15
Modified
2024-11-21 04:47
Severity ?
Summary
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | bmxnor0200h_firmware | * | |
| schneider-electric | bmxnor0200h | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AECF5778-C5F5-4789-BD3D-793B35DDDBDF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*",
"matchCriteriaId": "60D9A366-3394-4275-B884-AE6E7227156E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unusually high number of IEC 60870- 5-104 packets are received by the module on port 2404/TCP."
},
{
"lang": "es",
"value": "Una CWE-754: Se presenta una vulnerabilidad de Comprobaci\u00f3n Inapropiada de Condiciones Inusuales o Excepcionales en el m\u00f3dulo BMXNOR0200H Ethernet/Serial RTU (todas las versiones de firmware), lo que podr\u00eda causar la desconexi\u00f3n de las conexiones activas cuando un n\u00famero inusualmente alto de paquetes IEC 60870-5104 son recibidos por parte del m\u00f3dulo sobre el puerto 2404/TCP."
}
],
"id": "CVE-2019-6831",
"lastModified": "2024-11-21T04:47:14.383",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-17T20:15:12.343",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Broken Link"
],
"url": "https://security.cse.iitk.ac.in/responsible-disclosure"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://security.cse.iitk.ac.in/responsible-disclosure"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…