GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2019-13926

Vulnerability from fkie_nvd - Published: 2020-02-11 16:15 - Updated: 2026-06-17 02:17
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "SCALANCE S602",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0 and \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE S612",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0 and \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE S623",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0 and \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE S627-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0 and \u003c V4.1"
            }
          ]
        }
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "253D14CB-CD7E-40B0-8F3F-1D35FDC46658",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "340031C6-BD77-4601-AA35-4B3A85729576",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E518E7C-EDF2-4E6A-8C9F-7623FC66CC3F",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FA5FF74-3117-48F0-8AE6-658B180B7FF0",
              "versionEndExcluding": "4.1",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SCALANCE S602 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S612 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S623 (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1), SCALANCE S627-2M (Todas las versiones posteriores o iguales a V3.0 y anteriores a V4.1). Los paquetes especialmente dise\u00f1ados enviados hacia el puerto 443/tcp de los dispositivos afectados podr\u00edan causar una condici\u00f3n de Denegaci\u00f3n de Servicio del servidor web. Es requerido un reinicio en fr\u00edo para restaurar la funcionalidad del dispositivo"
    }
  ],
  "id": "CVE-2019-13926",
  "lastModified": "2026-06-17T02:17:25.747",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-02-11T16:15:14.680",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.