Summary
An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000119/ | Vendor Advisory | |
| ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/96721 | Third Party Advisory, VDB Entry | |
| ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-17-066-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000119/ | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/96721 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-17-066-01 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | tableau_desktop | 7.0 | |
| schneider-electric | tableau_desktop | 10.1.3 | |
| schneider-electric | tableau_server | 7.0 | |
| schneider-electric | tableau_server | 10.1.3 | |
| schneider-electric | wonderware_intelligence | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:tableau_desktop:7.0:*:*:*:*:*:*:*",
"matchCriteriaId": "2353C750-C7CA-4105-9431-ADBF2679A6AD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:tableau_desktop:10.1.3:*:*:*:*:*:*:*",
"matchCriteriaId": "5E68F958-A9A7-458A-B5FD-751F573EB0EA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:tableau_server:7.0:*:*:*:*:*:*:*",
"matchCriteriaId": "FA0E4513-4229-4E4B-946A-A706AAA7852F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:tableau_server:10.1.3:*:*:*:*:*:*:*",
"matchCriteriaId": "D068243A-F7D5-4577-BD75-A072DE93878F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:wonderware_intelligence:*:r3:*:*:*:*:*:*",
"matchCriteriaId": "AFF847C6-9765-45C4-B914-85031B0214C7",
"versionEndIncluding": "2014",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access."
},
{
"lang": "es",
"value": "Se ha descubierto un problema en Schneider Electric Tableau Server/Desktop Versions 7.0 a 10.1.3 en Wonderware Intelligence Versions 2014R3 y anteriores. Estas versiones contienen una cuenta de sistema que se instala por defecto. La cuenta de sistema por defecto es dificil de configurar sin credenciales por defecto tras la instalacci\u00f3n, y cambiar las credenciales por defecto en el Tableau Server incrustado no est\u00e1 documentado. Si Tableau Server se usa con la seguridad integrada de Windows (Active Directory), el software no es vulnerable. Sin embargo, cuando se utiliza Tableau Server con el modo de autenticaci\u00f3n local, el software es vulnerable. La cuenta de sistema por defecto puede ser usada para obtener acceso no autorizado."
}
],
"id": "CVE-2017-5178",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-03-08T08:59:00.160",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000119/"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/96721"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-066-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000119/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/96721"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-066-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…