FKIE_CVE-2016-10104
Vulnerability from fkie_nvd - Published: 2017-01-23 07:59 - Updated: 2026-05-13 00:24
Severity
Summary
Information Disclosure can occur in sshProfiles.jsd in Hitek Software's Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for SSH/SFTP profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.00:*:*:*:*:*:*:*",
"matchCriteriaId": "3A7C2457-43EB-4486-A120-B7D459FC279B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.01:*:*:*:*:*:*:*",
"matchCriteriaId": "35EAE4F6-29CE-4D20-8567-2220905A4783",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.02:*:*:*:*:*:*:*",
"matchCriteriaId": "722B055A-E157-46AA-9919-0BE7491B15E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.03:*:*:*:*:*:*:*",
"matchCriteriaId": "3913B250-2602-4943-A45E-407118445FBB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.04:*:*:*:*:*:*:*",
"matchCriteriaId": "6727427E-834D-42A8-8182-2C5FDFE520C0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.05:*:*:*:*:*:*:*",
"matchCriteriaId": "052CF7DA-98F0-4390-8FAE-5AF5F42708EC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.06:*:*:*:*:*:*:*",
"matchCriteriaId": "A83DAF2F-569D-433B-85E1-138AEADF4E0C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.07:*:*:*:*:*:*:*",
"matchCriteriaId": "42CC6578-8DFA-4500-AF77-9DC73834C8E8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.08:*:*:*:*:*:*:*",
"matchCriteriaId": "7AC7B1FF-1FB4-423C-BD9D-75DD6B6E66E6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.09:*:*:*:*:*:*:*",
"matchCriteriaId": "EEAC4542-BC4D-4DEA-8D7B-C750951E825F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.11:*:*:*:*:*:*:*",
"matchCriteriaId": "974AA5EF-9670-4DC6-89A2-DEDA3B3276D8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.12:*:*:*:*:*:*:*",
"matchCriteriaId": "DA0C77C1-D835-4539-809C-1D6E805D40AD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.13:*:*:*:*:*:*:*",
"matchCriteriaId": "E9FEEFF2-DB6B-472C-B2B7-C7C1D22DBA4C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.14:*:*:*:*:*:*:*",
"matchCriteriaId": "DA79A04C-D25D-4D3E-B131-D4249EE0DA4F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.15:*:*:*:*:*:*:*",
"matchCriteriaId": "474F086B-D331-498F-9313-159BC005BB17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.16:*:*:*:*:*:*:*",
"matchCriteriaId": "A17B080F-E6A3-4A3D-B600-22466C45C82C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.17:*:*:*:*:*:*:*",
"matchCriteriaId": "A464860D-5D5D-4065-A7C6-BBE5DC9139D1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.18:*:*:*:*:*:*:*",
"matchCriteriaId": "AF9197BC-92AB-4927-8805-494B39A2953A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.19:*:*:*:*:*:*:*",
"matchCriteriaId": "1B27121A-7B58-4548-935F-57C1FF187EE6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.20:*:*:*:*:*:*:*",
"matchCriteriaId": "073ED514-E2CC-4D18-A9F4-9654E9161727",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.21:*:*:*:*:*:*:*",
"matchCriteriaId": "9D27D639-94D1-4BDE-AD4E-AEB37AFABCE4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.22:*:*:*:*:*:*:*",
"matchCriteriaId": "43826AA5-62A0-4452-8EC4-098982867CA1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.23:*:*:*:*:*:*:*",
"matchCriteriaId": "DDEA6E6A-D111-4320-BF3A-E5B7CC397423",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.24:*:*:*:*:*:*:*",
"matchCriteriaId": "63FADFB7-14A0-4C13-8853-40EACFBDBD85",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:10.25:*:*:*:*:*:*:*",
"matchCriteriaId": "3F80CAE4-2A0D-4805-AAC3-0FFD44D39F78",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.00:*:*:*:*:*:*:*",
"matchCriteriaId": "61137963-5766-4F2E-B4A2-EDA5A4469720",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.01:*:*:*:*:*:*:*",
"matchCriteriaId": "C7682507-9EA1-468D-8D8C-7060F068EA61",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.02:*:*:*:*:*:*:*",
"matchCriteriaId": "BF9EAFEE-3A59-4350-903E-D46AC9185FFE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.03:*:*:*:*:*:*:*",
"matchCriteriaId": "0CD5DD65-A3DB-4F3F-A8CE-DEF6185D5648",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.04:*:*:*:*:*:*:*",
"matchCriteriaId": "00C18571-A34F-4B61-B7FA-3649E31BA513",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.05:*:*:*:*:*:*:*",
"matchCriteriaId": "7F7BE139-0DC5-4008-A974-D1A01E1758EC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.06:*:*:*:*:*:*:*",
"matchCriteriaId": "449AC115-FF3D-4D40-9D8A-8439625D3410",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.07:*:*:*:*:*:*:*",
"matchCriteriaId": "84A099DF-F17F-47A3-A17E-C397445A3430",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.08:*:*:*:*:*:*:*",
"matchCriteriaId": "4E680BB2-8E4B-407E-813E-661D8880DF5C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0A1EF835-E571-4985-96DC-1703BF3F3BFC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.11:*:*:*:*:*:*:*",
"matchCriteriaId": "E7C74206-9610-4725-8AB9-CEBD6213DD07",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.12:*:*:*:*:*:*:*",
"matchCriteriaId": "E4830A80-D9A8-48CB-B5AE-A36FB0BE7EB3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.13:*:*:*:*:*:*:*",
"matchCriteriaId": "E3FC908B-E1A7-4ED8-B6D2-A46CE87B96A1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:hiteksoftware:automize:11.14:*:*:*:*:*:*:*",
"matchCriteriaId": "90166099-D6E9-4346-9C24-1E2CB3FC2455",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Information Disclosure can occur in sshProfiles.jsd in Hitek Software\u0027s Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for SSH/SFTP profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14."
},
{
"lang": "es",
"value": "Puede ocurrir divulgaci\u00f3n de informaci\u00f3n en sshProfiles.jsd en Hitek Software\u0027s Automize debido a que el que el atributo Leer se establece para Usuarios. Esto permite a un atacante recuperar contrase\u00f1as cifradas para perfiles SSH/SFTP. Se verifica en todas las versiones hasta la 10.x incluyendo la 10.25 y todas las versiones hasta la 11.x incluyendo la 11.14."
}
],
"id": "CVE-2016-10104",
"lastModified": "2026-05-13T00:24:29.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-01-23T07:59:00.283",
"references": [
{
"source": "cve@mitre.org",
"url": "http://www.securityfocus.com/bid/96845"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://rastamouse.me/guff/2016/automize/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securityfocus.com/bid/96845"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://rastamouse.me/guff/2016/automize/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-326"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…