fkie_cve-2014-8511
Vulnerability from fkie_nvd
Published
2014-12-27 15:59
Modified
2025-04-12 10:46
Severity ?
Summary
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01 | ||
| cve@mitre.org | https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01 | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | proclima | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:proclima:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A09790AE-321A-44F3-9E93-EBC5F846F3F8",
"versionEndIncluding": "6.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers."
},
{
"lang": "es",
"value": "Desbordamiento de buffer en el control ActiveX en Atx45.ocx en Schneider Electric ProClima anterior a 6.1.7 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de vectores sin especificar, una vulnerabilidad diferente a CVE-2014-8512. NOTA: esto se puede clarificar despu\u00e9s en base a los detalles proporcionados por los investigadores."
}
],
"id": "CVE-2014-8511",
"lastModified": "2025-04-12T10:46:40.837",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2014-12-27T15:59:00.057",
"references": [
{
"source": "cve@mitre.org",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…