fkie_cve-2012-3037
Vulnerability from fkie_nvd
Published
2012-09-25 11:07
Modified
2025-04-11 00:51
Severity ?
Summary
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | http://en.securitylab.ru/lab/PT-2012-48 | Third Party Advisory | |
| ics-cert@hq.dhs.gov | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf | Broken Link, Vendor Advisory | |
| ics-cert@hq.dhs.gov | http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf | Broken Link, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://en.securitylab.ru/lab/PT-2012-48 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf | Broken Link, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf | Broken Link, Third Party Advisory, US Government Resource |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DBAF9260-5746-469B-AAB3-66F12108A610",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C1476AD3-CF60-462E-9EEF-616A1B510F88",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5A19DB02-8D64-4044-97BD-6769F3CE6AE5",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "406EC119-4B43-4AFD-9BC9-FE86E2F57F51",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A162C46-AB20-41EB-B76F-799BCEAF66F9",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "82B37AFD-DCE1-4244-BB70-1DCDA91B82C1",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "147E133F-E99A-4DDA-A77B-E3EAC59AB2EE",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8861261D-7153-4D30-8614-BA67BB3888C0",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8F5277B1-273F-4138-9C29-D2E25C6C21F1",
"versionEndExcluding": "3.0.0",
"versionStartIncluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate."
},
{
"lang": "es",
"value": "El PLC siemens SIMATIC S7-1200 2.x no protege de forma adecuada la clave privada del certificado de SIMATIC CONTROLLER Certification Authority, lo que permitir\u00eda a atacantes remotos espiar el servidor Web S7-1200 usando esta clave para crear certificados falsificados."
}
],
"id": "CVE-2012-3037",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2012-09-25T11:07:46.470",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory"
],
"url": "http://en.securitylab.ru/lab/PT-2012-48"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Broken Link",
"Third Party Advisory",
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "http://en.securitylab.ru/lab/PT-2012-48"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link",
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link",
"Third Party Advisory",
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-295"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…