GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2026-76704 (GCVE-0-2026-76704)

Vulnerability from cvelistv5 – Published: 2026-09-15 19:24 – Updated: 2026-09-15 19:46
VLAI
Title
Authenticated Stored Cross-Site Scripting (XSS) Vulnerability in EdgeConnect SD-WAN Orchestrator Web-Based Management Interface
Summary
A vulnerability in the web-based management interface of the EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to execute arbitrary script code in a victim's browser in the context of the affected interface. Successful exploitation could allow an attacker to access sensitive information, potentially affecting the confidentiality and integrity of the data processed by the application.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-15 19:46 UTC
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version CPE status
Hewlett Packard Enterprise (HPE) EdgeConnect SD-WAN Gateways Affected: 9.7.0 , ≤ 9.7.0 (semver)
Affected: 9.6.0 , ≤ 9.6.3 (semver)
Affected: 9.5.0 , ≤ 9.5.8 (semver)
Affected: 9.4.0 , ≤ 9.4.10 (semver)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-76704",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-15T19:46:37.961557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-15T19:46:52.153Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "EdgeConnect SD-WAN Gateways",
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "versions": [
            {
              "lessThanOrEqual": "9.7.0",
              "status": "affected",
              "version": "9.7.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.6.3",
              "status": "affected",
              "version": "9.6.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.5.8",
              "status": "affected",
              "version": "9.5.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "9.4.10",
              "status": "affected",
              "version": "9.4.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "This vulnerability was reported by m0x_noob to the HPE Networking Bug Bounty program."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of the EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface. Successful exploitation could allow an attacker to access sensitive information, potentially affecting the confidentiality and integrity of the data processed by the application."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-15T19:24:00.963Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us\u0026docLocale=en_US"
        }
      ],
      "source": {
        "advisory": "HPESBNW05135",
        "discovery": "INTERNAL"
      },
      "title": "Authenticated Stored Cross-Site Scripting (XSS) Vulnerability in EdgeConnect SD-WAN Orchestrator Web-Based Management Interface",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2026-76704",
    "datePublished": "2026-09-15T19:24:00.963Z",
    "dateReserved": "2026-08-19T16:12:09.681Z",
    "dateUpdated": "2026-09-15T19:46:52.153Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-76704",
      "date": "2026-09-18",
      "epss": "0.00249",
      "percentile": "0.16597"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "affected",
                "product": "EdgeConnect SD-WAN Gateways",
                "vendor": "Hewlett Packard Enterprise (HPE)",
                "versions": [
                  {
                    "lessThanOrEqual": "9.7.0",
                    "status": "affected",
                    "version": "9.7.0",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "9.6.3",
                    "status": "affected",
                    "version": "9.6.0",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "9.5.8",
                    "status": "affected",
                    "version": "9.5.0",
                    "versionType": "semver"
                  },
                  {
                    "lessThanOrEqual": "9.4.10",
                    "status": "affected",
                    "version": "9.4.0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "security-alert@hpe.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability in the web-based management interface of the EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface. Successful exploitation could allow an attacker to access sensitive information, potentially affecting the confidentiality and integrity of the data processed by the application."
          }
        ],
        "id": "CVE-2026-76704",
        "lastModified": "2026-09-16T19:21:55.793",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.3,
              "impactScore": 2.7,
              "source": "security-alert@hpe.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-76704",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-15T19:46:37.961557Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-09-15T20:17:54.943",
        "references": [
          {
            "source": "security-alert@hpe.com",
            "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us\u0026docLocale=en_US"
          }
        ],
        "sourceIdentifier": "security-alert@hpe.com",
        "vulnStatus": "Awaiting Analysis",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-76704",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-15T19:46:37.961557Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-79",
                    "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-15T19:46:49.160Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "EdgeConnect SD-WAN Gateways",
              "vendor": "Hewlett Packard Enterprise (HPE)",
              "versions": [
                {
                  "lessThanOrEqual": "9.7.0",
                  "status": "affected",
                  "version": "9.7.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "9.6.3",
                  "status": "affected",
                  "version": "9.6.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "9.5.8",
                  "status": "affected",
                  "version": "9.5.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "9.4.10",
                  "status": "affected",
                  "version": "9.4.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "This vulnerability was reported by m0x_noob to the HPE Networking Bug Bounty program."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in the web-based management interface of the EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to execute arbitrary script code in a victim\u0027s browser in the context of the affected interface. Successful exploitation could allow an attacker to access sensitive information, potentially affecting the confidentiality and integrity of the data processed by the application."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-15T19:24:00.963Z",
            "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
            "shortName": "hpe"
          },
          "references": [
            {
              "url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05135en_us\u0026docLocale=en_US"
            }
          ],
          "source": {
            "advisory": "HPESBNW05135",
            "discovery": "INTERNAL"
          },
          "title": "Authenticated Stored Cross-Site Scripting (XSS) Vulnerability in EdgeConnect SD-WAN Orchestrator Web-Based Management Interface",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "assignerShortName": "hpe",
        "cveId": "CVE-2026-76704",
        "datePublished": "2026-09-15T19:24:00.963Z",
        "dateReserved": "2026-08-19T16:12:09.681Z",
        "dateUpdated": "2026-09-15T19:46:52.153Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…