CVE-2026-71942 (GCVE-0-2026-71942)
Vulnerability from cvelistv5 – Published: 2026-08-24 17:08 – Updated: 2026-08-24 18:38
VLAI
EPSS
VEX
Title
DrayTek VigorSwitch Multiple Models Buffer Overflow via mail_mailalert
Summary
Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device's web management interface.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-24 18:37 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.draytek.com/about/security-advisory/m… | vendor-advisory |
| https://www.vulncheck.com/advisories/draytek-vigo… | third-party-advisory |
Impacted products
28 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| DrayTek Corporation | VigorSwitch G2540xs |
Affected:
0 , < 3.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2540xs |
Affected:
0 , < 3.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch FX2120 |
Affected:
0 , < 3.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G2282x |
Affected:
0 , < 2.10.6
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2282x |
Affected:
0 , < 2.10.6
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch Q2300x |
Affected:
0 , < 2.10.7
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch PQ2300xb |
Affected:
0 , < 2.10.7
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G2542x |
Affected:
0 , < 3.10.6
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2542x |
Affected:
0 , < 3.10.6
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2542xh |
Affected:
0 , < 3.10.6
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch PX2060 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G1280 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P1280 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P1281x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G1282 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P1282 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G2121 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2121 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch PQ2121x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch Q2121x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G2280x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2280x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch Q2200x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch PQ2200xb |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G2100 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2100 |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch G2540x |
Affected:
0 , < 2.9.10
(custom)
|
guessed | |
| DrayTek Corporation | VigorSwitch P2540x |
Affected:
0 , < 2.9.10
(custom)
|
guessed |
Date Public
2026-08-24 00:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-71942",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-24T18:37:40.430897Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-24T18:38:01.010Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2540xs",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2540xs",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch FX2120",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2282x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2282x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2300x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2300xb",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2542x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2542x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2542xh",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PX2060",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G1280",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1280",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1281x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G1282",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1282",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2121",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2121",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2121x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2121x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2280x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2280x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2200x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2200xb",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2100",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2100",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2540x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2540x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_g2540xs_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_p2540xs_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_fx2120_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_g1282_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_p1282_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_g2121_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_pq2121x_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_q2121x_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_g2280x_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_p2280x_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_q2200x_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_pq2200xb_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_g2100_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:draytek:vigorswitch_p2100_firmware:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2.9.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jincheng Wang (@winmt)"
},
{
"lang": "en",
"type": "finder",
"value": "Le Yu (Nanjing University of Posts and Telecommunications)"
},
{
"lang": "en",
"type": "finder",
"value": "Xiapu Luo (The Hong Kong Polytechnic University)"
}
],
"datePublic": "2026-08-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device\u0027s web management interface."
}
],
"metrics": [
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH"
},
"format": "CVSS"
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-24T17:08:05.410Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/"
},
{
"name": "VulnCheck Advisory: DrayTek VigorSwitch Multiple Models Buffer Overflow via mail_mailalert",
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-buffer-overflow-via-mail-mailalert"
}
],
"title": "DrayTek VigorSwitch Multiple Models Buffer Overflow via mail_mailalert",
"x_generator": {
"engine": "vulncheck-endgame"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-71942",
"datePublished": "2026-08-24T17:08:05.410Z",
"dateReserved": "2026-08-08T16:37:44.519Z",
"dateUpdated": "2026-08-24T18:38:01.010Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-71942\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2026-08-24T18:17:19.877\",\"lastModified\":\"2026-08-24T19:16:57.680\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device\u0027s web management interface.\"}],\"affected\":[{\"source\":\"disclosure@vulncheck.com\",\"affectedData\":[{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2540xs\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"3.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2540xs\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"3.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch FX2120\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"3.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2282x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.10.6\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2282x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.10.6\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch Q2300x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.10.7\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch PQ2300xb\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.10.7\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2542x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"3.10.6\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2542x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"3.10.6\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2542xh\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"3.10.6\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch PX2060\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G1280\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P1280\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P1281x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G1282\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P1282\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2121\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2121\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch PQ2121x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch Q2121x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2280x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2280x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch Q2200x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch PQ2200xb\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2100\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2100\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch G2540x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]},{\"vendor\":\"DrayTek Corporation\",\"product\":\"VigorSwitch P2540x\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"2.9.10\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-08-24T18:37:40.430897Z\",\"id\":\"CVE-2026-71942\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-buffer-overflow-via-mail-mailalert\",\"source\":\"disclosure@vulncheck.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-71942\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-08-24T18:37:40.430897Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-08-24T18:37:56.353Z\"}}], \"cna\": {\"title\": \"DrayTek VigorSwitch Multiple Models Buffer Overflow via mail_mailalert\", \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Jincheng Wang (@winmt)\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Le Yu (Nanjing University of Posts and Telecommunications)\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Xiapu Luo (The Hong Kong Polytechnic University)\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.6, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"HIGH\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\"}}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.2, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2540xs\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2540xs\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch FX2120\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2282x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.10.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2282x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.10.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch Q2300x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.10.7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch PQ2300xb\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.10.7\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2542x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.10.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2542x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.10.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2542xh\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.10.6\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch PX2060\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G1280\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P1280\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P1281x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G1282\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P1282\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2121\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2121\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch PQ2121x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch Q2121x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2280x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2280x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch Q2200x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch PQ2200xb\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2100\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2100\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch G2540x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"DrayTek Corporation\", \"product\": \"VigorSwitch P2540x\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.9.10\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-08-24T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-buffer-overflow-via-mail-mailalert\", \"name\": \"VulnCheck Advisory: DrayTek VigorSwitch Multiple Models Buffer Overflow via mail_mailalert\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"vulncheck-endgame\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device\u0027s web management interface.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_g2540xs_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"3.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_p2540xs_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"3.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_fx2120_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"3.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_g1282_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_p1282_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_g2121_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_pq2121x_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_q2121x_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_g2280x_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_p2280x_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_q2200x_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_pq2200xb_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_g2100_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}, {\"criteria\": \"cpe:2.3:o:draytek:vigorswitch_p2100_firmware:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndExcluding\": \"2.9.10\"}], \"operator\": \"OR\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2026-08-24T17:08:05.410Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-71942\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-08-24T18:38:01.010Z\", \"dateReserved\": \"2026-08-08T16:37:44.519Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2026-08-24T17:08:05.410Z\", \"assignerShortName\": \"VulnCheck\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…