CVE-2025-9994 (GCVE-0-2025-9994)

Vulnerability from cvelistv5 – Published: 2025-09-09 13:01 – Updated: 2025-11-03 18:14
VLAI?
Title
Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not require authentication
Summary
The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access.
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-9994",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T13:17:17.857837Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-306",
                "description": "CWE-306 Missing Authentication for Critical Function",
                "lang": "en",
                "type": "CWE"
              }
            ]
          },
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-10T13:44:29.899Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T18:14:27.694Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.kb.cert.org/vuls/id/763183"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BT-AP 111",
          "vendor": "Amped RF",
          "versions": [
            {
              "status": "affected",
              "version": "*"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Amp\u2019ed RF BT-AP 111 Bluetooth access point\u0027s HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en"
            }
          ]
        },
        {
          "descriptions": [
            {
              "description": "CWE-287 Improper Authentication",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T13:01:05.384Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "url": "https://www.ampedrftech.com/guides/BT-AP111_UserManual.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Amp\u2019ed RF BT-AP 111 Bluetooth access point\u0027s HTTP admin interface does not require authentication",
      "x_generator": {
        "engine": "VINCE 3.0.24",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2025-9994"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2025-9994",
    "datePublished": "2025-09-09T13:01:05.384Z",
    "dateReserved": "2025-09-04T15:31:44.614Z",
    "dateUpdated": "2025-11-03T18:14:27.694Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-9994\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2025-09-09T14:15:49.943\",\"lastModified\":\"2025-11-03T19:16:18.503\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Amp\u2019ed RF BT-AP 111 Bluetooth access point\u0027s HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"},{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"references\":[{\"url\":\"https://www.ampedrftech.com/guides/BT-AP111_UserManual.pdf\",\"source\":\"cret@cert.org\"},{\"url\":\"https://www.kb.cert.org/vuls/id/763183\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9994\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-10T13:17:17.857837Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-287\", \"description\": \"CWE-287 Improper Authentication\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-10T13:17:21.561Z\"}}], \"cna\": {\"title\": \"Amp\\u2019ed RF BT-AP 111 Bluetooth access point\u0027s HTTP admin interface does not require authentication\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"affected\": [{\"vendor\": \"Amped RF\", \"product\": \"BT-AP 111\", \"versions\": [{\"status\": \"affected\", \"version\": \"*\"}]}], \"references\": [{\"url\": \"https://www.ampedrftech.com/guides/BT-AP111_UserManual.pdf\"}], \"x_generator\": {\"env\": \"prod\", \"engine\": \"VINCE 3.0.24\", \"origin\": \"https://cveawg.mitre.org/api/cve/CVE-2025-9994\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Amp\\u2019ed RF BT-AP 111 Bluetooth access point\u0027s HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-306 Missing Authentication for Critical Function\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"description\": \"CWE-287 Improper Authentication\"}]}], \"providerMetadata\": {\"orgId\": \"37e5125f-f79b-445b-8fad-9564f167944b\", \"shortName\": \"certcc\", \"dateUpdated\": \"2025-09-09T13:01:05.384Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-9994\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-10T13:44:29.899Z\", \"dateReserved\": \"2025-09-04T15:31:44.614Z\", \"assignerOrgId\": \"37e5125f-f79b-445b-8fad-9564f167944b\", \"datePublished\": \"2025-09-09T13:01:05.384Z\", \"assignerShortName\": \"certcc\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…