CVE-2025-9161 (GCVE-0-2025-9161)
Vulnerability from cvelistv5
Published
2025-09-09 12:57
Modified
2025-09-09 13:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Summary
A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Rockwell Automation | FactoryTalk Optix |
Version: All Versions 1.5.0 - 1.5.7 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-9161", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-09-09T13:18:39.142088Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-09-09T13:18:44.719Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk Optix", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "All Versions 1.5.0 - 1.5.7" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e" } ], "value": "A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution." } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "HIGH", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 7.3, "baseSeverity": "HIGH", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "ACTIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-09-09T12:57:40.934Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1742.html" } ], "source": { "advisory": "SD1742", "discovery": "INTERNAL" }, "title": "Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2025-9161", "datePublished": "2025-09-09T12:57:40.934Z", "dateReserved": "2025-08-19T13:03:36.727Z", "dateUpdated": "2025-09-09T13:18:44.719Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-9161\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2025-09-09T13:15:32.830\",\"lastModified\":\"2025-09-09T16:28:43.660\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1742.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9161\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-09T13:18:39.142088Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-09T13:18:41.100Z\"}}], \"cna\": {\"title\": \"Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability\", \"source\": {\"advisory\": \"SD1742\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 7.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"ACTIVE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"FactoryTalk Optix\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions 1.5.0 - 1.5.7\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1742.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eA security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution. \u003c/span\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003e\u0026nbsp;\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2025-09-09T12:57:40.934Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-9161\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-09T13:18:44.719Z\", \"dateReserved\": \"2025-08-19T13:03:36.727Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2025-09-09T12:57:40.934Z\", \"assignerShortName\": \"Rockwell\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…