CVE-2025-8827 (GCVE-0-2025-8827)
Vulnerability from cvelistv5
Published
2025-08-11 03:02
Modified
2025-08-12 14:21
Severity ?
2.1 (Low) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RC:R
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
▼ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.319361 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.319361 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.626692 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.linksys.com/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md | Exploit, Third Party Advisory | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc | Exploit, Third Party Advisory |
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-8827", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-08-12T14:21:11.472745Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-12T14:21:14.853Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc" }, { "tags": [ "exploit" ], "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "RE6250", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "20250801" } ] }, { "product": "RE6300", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "20250801" } ] }, { "product": "RE6350", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "20250801" } ] }, { "product": "RE6500", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "20250801" } ] }, { "product": "RE7000", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "20250801" } ] }, { "product": "RE9000", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "20250801" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "pjq123 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es geht hierbei um die Funktion um_inspect_cross_band der Datei /goform/RP_setBasicAuto. Durch das Beeinflussen des Arguments staticGateway mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "OS Command Injection", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-77", "description": "Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-11T03:02:06.170Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-319361 | Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.319361" }, { "name": "VDB-319361 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.319361" }, { "name": "Submit #626692 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.626692" }, { "tags": [ "related" ], "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md" }, { "tags": [ "exploit" ], "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc" }, { "tags": [ "product" ], "url": "https://www.linksys.com/" } ], "timeline": [ { "lang": "en", "time": "2025-08-10T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-08-10T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-08-10T10:11:49.000Z", "value": "VulDB entry last update" } ], "title": "Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-8827", "datePublished": "2025-08-11T03:02:06.170Z", "dateReserved": "2025-08-10T07:53:59.145Z", "dateUpdated": "2025-08-12T14:21:14.853Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-8827\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-08-11T04:15:44.160\",\"lastModified\":\"2025-09-04T18:37:10.320\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Se encontr\u00f3 una vulnerabilidad en los Linksys RE6250, RE6300, RE6350, RE6500, RE7000 y RE9000 hasta la versi\u00f3n 20250801. Este problema afecta a la funci\u00f3n um_inspect_cross_band del archivo /goform/RP_setBasicAuto. La manipulaci\u00f3n del argumento staticGateway provoca la inyecci\u00f3n de comandos del sistema operativo. El ataque puede iniciarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"},{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70728D67-153A-49FA-80E2-0DE9086DA253\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"898FD49F-4225-47FF-822C-9E4FFB5EE192\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E3A6A93-D598-4F52-808C-EAA45B468066\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"25647318-6422-418C-99B8-C806FF490028\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FFD3F65-E520-415D-BAB8-57FACEA5BEC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DC2325A-068F-4B5E-A365-6BF1103E320E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D04E83B6-EE99-42EB-AA37-895B1467CEDA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11F24125-412F-473A-BF34-02284F8DAC2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7424D2C2-BCF4-4B2D-BE59-71B50B13FE77\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"92354C9C-D1B2-4143-803D-DE5EF7842184\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52622B22-2E42-443B-81DA-7C42ECCF0564\"}]}]}],\"references\":[{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.319361\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.319361\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.626692\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.linksys.com/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}", "vulnrichment": { "containers": "{\"cna\": {\"title\": \"Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"pjq123 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"Linksys\", \"product\": \"RE6250\", \"versions\": [{\"status\": \"affected\", \"version\": \"20250801\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6300\", \"versions\": [{\"status\": \"affected\", \"version\": \"20250801\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6350\", \"versions\": [{\"status\": \"affected\", \"version\": \"20250801\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6500\", \"versions\": [{\"status\": \"affected\", \"version\": \"20250801\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE7000\", \"versions\": [{\"status\": \"affected\", \"version\": \"20250801\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"20250801\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-08-10T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-08-10T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-08-10T10:11:49.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.319361\", \"name\": \"VDB-319361 | Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.319361\", \"name\": \"VDB-319361 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.626692\", \"name\": \"Submit #626692 | Linksys RE6500\\u3001RE6250\\u3001RE6300\\u3001RE6350\\u3001RE7000\\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md\", \"tags\": [\"related\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.linksys.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Es geht hierbei um die Funktion um_inspect_cross_band der Datei /goform/RP_setBasicAuto. Durch das Beeinflussen des Arguments staticGateway mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"OS Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-08-11T03:02:06.170Z\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-8827\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-12T14:21:11.472745Z\"}}}], \"references\": [{\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md#poc\", \"tags\": [\"exploit\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys1/vuln_43/43.md\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"shortName\": \"CISA-ADP\", \"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"dateUpdated\": \"2025-08-12T14:21:02.994Z\"}}]}", "cveMetadata": "{\"cveId\": \"CVE-2025-8827\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-11T03:02:06.170Z\", \"dateReserved\": \"2025-08-10T07:53:59.145Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-08-11T03:02:06.170Z\", \"assignerShortName\": \"VulDB\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…