CVE-2025-7746 (GCVE-0-2025-7746)
Vulnerability from cvelistv5
Published
2025-09-09 21:02
Modified
2025-09-10 16:10
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Summary
CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7746",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T13:40:20.821038Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-10T16:10:34.376Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ILC992 InterLink Converter",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ATV340E Altivar Machine Drives",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ATV6000 Medium Voltage Altivar Process Drives",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ATS490 Altivar Soft Starter",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VW3A3530D: ATVdPAC module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "v25.0",
              "status": "affected",
              "version": "all versions",
              "versionType": "version"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T04:01:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
            }
          ],
          "value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T21:02:08.936Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2025-7746",
    "datePublished": "2025-09-09T21:02:08.936Z",
    "dateReserved": "2025-07-17T09:10:51.541Z",
    "dateUpdated": "2025-09-10T16:10:34.376Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-7746\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2025-09-09T21:15:39.353\",\"lastModified\":\"2025-09-11T17:14:25.240\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\u2019s browser.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"LOW\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf\",\"source\":\"cybersecurity@se.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-7746\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-10T13:40:20.821038Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-10T16:10:19.075Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"LOW\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ILC992 InterLink Converter\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATV340E Altivar Machine Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATV6000 Medium Voltage Altivar Process Drives\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"ATS490 Altivar Soft Starter\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"VW3A3720 \u0026 VW3A3721 Altivar Process Communication Modules\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Schneider Electric\", \"product\": \"VW3A3530D: ATVdPAC module\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\", \"lessThan\": \"v25.0\", \"versionType\": \"version\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-09-09T04:01:00.000Z\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-252-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2025-252-01.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\\u2019s browser.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim\\u2019s browser.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2025-09-09T21:02:08.936Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-7746\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-10T16:10:34.376Z\", \"dateReserved\": \"2025-07-17T09:10:51.541Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2025-09-09T21:02:08.936Z\", \"assignerShortName\": \"schneider\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…