CVE-2025-66176 (GCVE-0-2025-66176)
Vulnerability from cvelistv5 – Published: 2026-01-13 01:47 – Updated: 2026-07-09 06:21
VLAI
EPSS
VEX
Summary
There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-13 14:32 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
18 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Hikvision | DS-K1T331 |
Affected:
Versions below V3.7.80
|
guessed | |
| Hikvision | DS-K1T341A/K1T341B |
Affected:
Versions below V3.7.80
|
guessed | |
| Hikvision | DS-K1T671/K5671 |
Affected:
Versions below V3.7.80
|
guessed | |
| Hikvision | DS-K1T672 |
Affected:
Versions below V3.7.80
|
guessed | |
| Hikvision | DS-K1T680 |
Affected:
Versions below V3.7.80
|
guessed | |
| Hikvision | DS-K1T981 |
Affected:
Versions below V3.7.80
|
guessed | |
| Hikvision | DS-K1T341C |
Affected:
Versions below V3.3.180
|
guessed | |
| Hikvision | DS-K1T670/K1T673 |
Affected:
Versions below V4.48.0
|
guessed | |
| Hikvision | DS-K1T8003 |
Affected:
Versions below V1.4.21
|
guessed | |
| Hikvision | DS-K1T804A |
Affected:
Versions below V1.4.22
|
guessed | |
| Hikvision | DS-K1T8003/8004 |
Affected:
Versions below V1.4.21
|
guessed | |
| Hikvision | DS-K1T804B |
Affected:
Versions below V1.4.23
|
guessed | |
| Hikvision | DS-K1T201A/K1T105A |
Affected:
Versions below V1.3.65
|
guessed | |
| Hikvision | DS-K1T342/K1T343/K1T344/DS-K1T6QT-F72/F43 |
Affected:
Versions below V4.48.0
|
guessed | |
| Hikvision | DS-K1T8005/DS-K1T808 |
Affected:
Versions below V3.25.40
|
guessed | |
| Hikvision | DS-K1T320/DS-K1T321 |
Affected:
Versions below V3.9.40
|
guessed | |
| Hikvision | DS-K1T323/DS-K1T510 |
Affected:
Versions below V4.23.41
|
guessed | |
| Hikvision | DS-K5033 |
Affected:
Versions below V4.37.40
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66176",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-13T14:32:35.447766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T17:28:04.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-03-18T15:28:09.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2281"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DS-K1T331",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T341A/K1T341B",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T671/K5671",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T672",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T680",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T981",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T341C",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.3.180"
}
]
},
{
"product": "DS-K1T670/K1T673",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.48.0"
}
]
},
{
"product": "DS-K1T8003",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.21"
}
]
},
{
"product": "DS-K1T804A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.22"
}
]
},
{
"product": "DS-K1T8003/8004",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.21"
}
]
},
{
"product": "DS-K1T804A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.22"
}
]
},
{
"product": "DS-K1T804B",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.23"
}
]
},
{
"product": "DS-K1T201A/K1T105A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.3.65"
}
]
},
{
"product": "DS-K1T342/K1T343/K1T344/DS-K1T6QT-F72/F43",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.48.0"
}
]
},
{
"product": "DS-K1T8005/DS-K1T808",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.25.40"
}
]
},
{
"product": "DS-K1T320/DS-K1T321",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.9.40"
}
]
},
{
"product": "DS-K1T323/DS-K1T510",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.23.41"
}
]
},
{
"product": "DS-K5033",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.37.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matt Wiseman of Cisco Talos"
}
],
"descriptions": [
{
"lang": "en",
"value": "There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-09T06:21:34.763Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/buffer-overflow-vulnerabilities-in-some-hikvision-products/"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2025-66176",
"datePublished": "2026-01-13T01:47:27.191Z",
"dateReserved": "2025-11-24T08:59:35.903Z",
"dateUpdated": "2026-07-09T06:21:34.763Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-66176",
"date": "2026-09-22",
"epss": "0.00475",
"percentile": "0.40236"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "DS-K1T331",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T341A/K1T341B",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T671/K5671",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T672",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T680",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T981",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T341C",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.3.180"
}
]
},
{
"product": "DS-K1T670/K1T673",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.48.0"
}
]
},
{
"product": "DS-K1T8003",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.21"
}
]
},
{
"product": "DS-K1T804A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.22"
}
]
},
{
"product": "DS-K1T8003/8004",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.21"
}
]
},
{
"product": "DS-K1T804A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.22"
}
]
},
{
"product": "DS-K1T804B",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.23"
}
]
},
{
"product": "DS-K1T201A/K1T105A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.3.65"
}
]
},
{
"product": "DS-K1T342/K1T343/K1T344/DS-K1T6QT-F72/F43",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.48.0"
}
]
},
{
"product": "DS-K1T8005/DS-K1T808",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.25.40"
}
]
},
{
"product": "DS-K1T320/DS-K1T321",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.9.40"
}
]
},
{
"product": "DS-K1T323/DS-K1T510",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.23.41"
}
]
},
{
"product": "DS-K5033",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.37.40"
}
]
}
],
"source": "hsrc@hikvision.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t331_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3FEF4CC2-2B13-4A80-8C57-68600AE9C93A",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t331:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9C6570A0-091A-49E4-8B04-650397FBD93D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t341a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0B6CAC82-004C-4919-9234-89004136537D",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t341a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "595B2854-FCC2-4DC9-9821-7545FE940FAC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t341b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA1A7F5D-F33C-4F15-8639-30CDCD7C1455",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t341b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3A7C6C26-52D1-4E9D-8448-29B78F692448",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t671_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7841DA8E-1AE6-46F6-BB86-360B8624F85D",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t671:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B322AE4-4BE3-46EE-BFFD-730274270D52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k5671_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9362042E-F45C-43E3-9709-3D17DE1E476A",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k5671:-:*:*:*:*:*:*:*",
"matchCriteriaId": "33DF42F9-AA7B-4275-A0F5-6CD1C395379F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t672_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A68F9962-7C8E-46AF-BFA2-372191D585AA",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t672:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58E41B4D-6601-4F72-BE90-1A119FFB3A0A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t680_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E4F9199C-DEAD-430C-B2A7-FF493DAEB8EA",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t680:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9166334C-35C0-4220-AF7B-1964E32B4451",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t981_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AA7CA850-60FF-4A8D-8B48-A0F92CA3C893",
"versionEndExcluding": "3.7.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t981:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF7DF3E8-F9C0-4475-B67B-DF390F6FCEA2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t341c_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D45B0E65-1F34-432B-98F3-4BD668BFDBFB",
"versionEndExcluding": "3.3.180",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t341c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "592F9F35-4C09-4EF2-BA57-D0A2A1DD9CAD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t670_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "938D48C8-CABA-4BA8-AF8C-F3A32E9B5FF5",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t670:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4DB9DCF-7203-4A56-8532-55930891BB1C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t673_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D8CA557-266F-415B-8470-BDD7D7082C65",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t673:-:*:*:*:*:*:*:*",
"matchCriteriaId": "317F27A1-FA60-4970-B59E-FB02C81E94FE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t8003_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "807EF865-6176-4B6B-B054-53371272C007",
"versionEndIncluding": "1.4.21",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t8003:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D63B00A4-6461-49E1-812C-6A4C3134A18F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t804a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "477FD324-96CA-4918-A757-A42AB88F99E7",
"versionEndExcluding": "1.4.22",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t804a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BDBE9E6-0A47-4D1E-824D-27CDD64EC9C6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t804b_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "55487C7C-A732-4572-8305-A5CEB4ABCE4F",
"versionEndExcluding": "1.4.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t804b:-:*:*:*:*:*:*:*",
"matchCriteriaId": "84AEF3D6-96C3-48DB-84F4-91B15DA10AC9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t201a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1C291558-9518-45FD-B335-4C4B0B809689",
"versionEndExcluding": "1.3.65",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t201a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F9AF2454-7567-404C-9034-B68D83AFE1A3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t105a_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2BE71E15-75EB-45E2-8132-6EC4328119D8",
"versionEndExcluding": "1.3.65",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t105a:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E016D61D-1B25-4771-A309-AA644A26C877",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t342_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EF448E78-1DD8-414D-8AE3-72A259FD3FAE",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t342:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8A163CD9-37C7-4575-A790-982E2406A01F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t343_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA984C23-17E5-43B4-A9DA-F5BD4B007478",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t343:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AB3816C5-A0F2-47B1-9B40-A47FE1FBE053",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t344_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0D6FF3E3-D6AB-4C69-8212-38397FB5C12B",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t344:-:*:*:*:*:*:*:*",
"matchCriteriaId": "52FE66AC-596D-494C-9C29-6919205ED5AC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t6qt-f72_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F6ABABF4-81D5-452B-8CC4-924335CF31F5",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t6qt-f72:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B48535B-1471-4B1C-AF8C-2F5116225F8A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t6qt-f43_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E83C60D7-B7FB-461E-B7E2-3EB2227C4F4E",
"versionEndExcluding": "4.48.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t6qt-f43:-:*:*:*:*:*:*:*",
"matchCriteriaId": "059E5A01-4633-40F9-9AA3-8F3019903835",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t8005_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "557CAE23-96F3-4A21-9E0D-532E54CED359",
"versionEndExcluding": "3.25.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t8005:-:*:*:*:*:*:*:*",
"matchCriteriaId": "696ED009-67B1-4D45-9AFD-BC68697A9D7A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t808_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8D81291F-D1C6-471D-B313-BE682B1D7C2B",
"versionEndExcluding": "3.25.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t808:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9B365695-11F0-4D2E-B7DD-EE6D78D95061",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t320_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C08D0733-7443-442D-9625-98DF738DE421",
"versionEndExcluding": "3.9.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t320:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFB55E0E-26EF-4A02-A875-0CDFC0E84494",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t321_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6E472A20-599F-4569-93CA-D0589A91C094",
"versionEndExcluding": "3.9.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t321:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0A726724-CA0C-4DF4-8766-DBC24CFC6298",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t323_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "72A9D0A0-440A-4478-9DFF-938A78949A22",
"versionEndExcluding": "4.23.41",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t323:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F1E2E44-BE3B-4BBA-8F99-7F825CFCCB04",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k1t510_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "56334187-6AE7-4A35-8597-6D3F84C2595B",
"versionEndExcluding": "4.23.41",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k1t510:-:*:*:*:*:*:*:*",
"matchCriteriaId": "29A292CB-0B20-4157-A1D6-B56AAA7796C1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hikvision:ds-k5033_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "133AA7CA-18AD-4D11-B2D7-222D8983FBEC",
"versionEndExcluding": "4.37.40",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hikvision:ds-k5033:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5949CA0B-49F3-4031-A636-3B634246E3AB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device."
},
{
"lang": "es",
"value": "Hay una vulnerabilidad de desbordamiento de pila en la funci\u00f3n de b\u00fasqueda y descubrimiento de dispositivos de los productos de control de acceso de Hikvision. Si se explota, un atacante en la misma red de \u00e1rea local (LAN) podr\u00eda causar un mal funcionamiento del dispositivo enviando paquetes especialmente dise\u00f1ados a un dispositivo sin parchear."
}
],
"id": "CVE-2025-66176",
"lastModified": "2026-07-09T07:16:21.267",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "hsrc@hikvision.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-66176",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-13T14:32:35.447766Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-01-13T03:16:01.097",
"references": [
{
"source": "hsrc@hikvision.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/buffer-overflow-vulnerabilities-in-some-hikvision-products/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2281"
}
],
"sourceIdentifier": "hsrc@hikvision.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2026-03-18T15:28:09.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2025-2281"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-66176",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-13T14:32:35.447766Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T14:32:38.543Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DS-K1T331",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T341A/K1T341B",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T671/K5671",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T672",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T680",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T981",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.7.80"
}
]
},
{
"product": "DS-K1T341C",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.3.180"
}
]
},
{
"product": "DS-K1T670/K1T673",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.48.0"
}
]
},
{
"product": "DS-K1T8003",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.21"
}
]
},
{
"product": "DS-K1T804A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.22"
}
]
},
{
"product": "DS-K1T8003/8004",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.21"
}
]
},
{
"product": "DS-K1T804A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.22"
}
]
},
{
"product": "DS-K1T804B",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.4.23"
}
]
},
{
"product": "DS-K1T201A/K1T105A",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V1.3.65"
}
]
},
{
"product": "DS-K1T342/K1T343/K1T344/DS-K1T6QT-F72/F43",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.48.0"
}
]
},
{
"product": "DS-K1T8005/DS-K1T808",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.25.40"
}
]
},
{
"product": "DS-K1T320/DS-K1T321",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V3.9.40"
}
]
},
{
"product": "DS-K1T323/DS-K1T510",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.23.41"
}
]
},
{
"product": "DS-K5033",
"vendor": "Hikvision",
"versions": [
{
"status": "affected",
"version": "Versions below V4.37.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matt Wiseman of Cisco Talos"
}
],
"descriptions": [
{
"lang": "en",
"value": "There is a Buffer overflow Vulnerability in the device Search and Discovery feature of Hikvision Access Control Products. If exploited, an attacker on the same local area network (LAN) could cause the device to malfunction by sending specially crafted packets to an unpatched device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-09T06:21:34.763Z",
"orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"shortName": "hikvision"
},
"references": [
{
"url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/buffer-overflow-vulnerabilities-in-some-hikvision-products/"
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
"assignerShortName": "hikvision",
"cveId": "CVE-2025-66176",
"datePublished": "2026-01-13T01:47:27.191Z",
"dateReserved": "2025-11-24T08:59:35.903Z",
"dateUpdated": "2026-07-09T06:21:34.763Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…