CVE-2025-5441 (GCVE-0-2025-5441)
Vulnerability from cvelistv5
Published
2025-06-02 10:31
Modified
2025-06-02 12:10
Severity ?
5.3 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
Summary
A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Linksys | RE6500 |
Version: 1.0.013.001 Version: 1.0.04.001 Version: 1.0.04.002 Version: 1.1.05.003 Version: 1.2.07.001 |
||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5441", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-06-02T12:06:07.017938Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-02T12:10:19.108Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "RE6500", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "1.0.013.001" }, { "status": "affected", "version": "1.0.04.001" }, { "status": "affected", "version": "1.0.04.002" }, { "status": "affected", "version": "1.1.05.003" }, { "status": "affected", "version": "1.2.07.001" } ] }, { "product": "RE6250", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "1.0.013.001" }, { "status": "affected", "version": "1.0.04.001" }, { "status": "affected", "version": "1.0.04.002" }, { "status": "affected", "version": "1.1.05.003" }, { "status": "affected", "version": "1.2.07.001" } ] }, { "product": "RE6300", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "1.0.013.001" }, { "status": "affected", "version": "1.0.04.001" }, { "status": "affected", "version": "1.0.04.002" }, { "status": "affected", "version": "1.1.05.003" }, { "status": "affected", "version": "1.2.07.001" } ] }, { "product": "RE6350", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "1.0.013.001" }, { "status": "affected", "version": "1.0.04.001" }, { "status": "affected", "version": "1.0.04.002" }, { "status": "affected", "version": "1.1.05.003" }, { "status": "affected", "version": "1.2.07.001" } ] }, { "product": "RE7000", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "1.0.013.001" }, { "status": "affected", "version": "1.0.04.001" }, { "status": "affected", "version": "1.0.04.002" }, { "status": "affected", "version": "1.1.05.003" }, { "status": "affected", "version": "1.2.07.001" } ] }, { "product": "RE9000", "vendor": "Linksys", "versions": [ { "status": "affected", "version": "1.0.013.001" }, { "status": "affected", "version": "1.0.04.001" }, { "status": "affected", "version": "1.0.04.002" }, { "status": "affected", "version": "1.1.05.003" }, { "status": "affected", "version": "1.2.07.001" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "pjqwudi (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Es geht um die Funktion setDeviceURL der Datei /goform/setDeviceURL. Durch Manipulieren des Arguments DeviceURL mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "OS Command Injection", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-77", "description": "Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-02T10:31:04.552Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-310780 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.310780" }, { "name": "VDB-310780 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.310780" }, { "name": "Submit #584363 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.584363" }, { "tags": [ "exploit" ], "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_4/4.md" }, { "tags": [ "product" ], "url": "https://www.linksys.com/" } ], "timeline": [ { "lang": "en", "time": "2025-06-01T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-01T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-01T19:11:48.000Z", "value": "VulDB entry last update" } ], "title": "Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5441", "datePublished": "2025-06-02T10:31:04.552Z", "dateReserved": "2025-06-01T17:06:22.538Z", "dateUpdated": "2025-06-02T12:10:19.108Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2025-5441\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-06-02T11:15:23.060\",\"lastModified\":\"2025-06-02T17:32:17.397\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 una vulnerabilidad cr\u00edtica en los Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la funci\u00f3n setDeviceURL del archivo /goform/setDeviceURL. La manipulaci\u00f3n del argumento DeviceURL provoca la inyecci\u00f3n de comandos del sistema operativo. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"},{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_4/4.md\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.310780\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.310780\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.584363\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://www.linksys.com/\",\"source\":\"cna@vuldb.com\"}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5441\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-02T12:06:07.017938Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-02T12:10:08.226Z\"}}], \"cna\": {\"title\": \"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"pjqwudi (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\"}}], \"affected\": [{\"vendor\": \"Linksys\", \"product\": \"RE6500\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6250\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6300\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6350\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE7000\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-06-01T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-06-01T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-06-01T19:11:48.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.310780\", \"name\": \"VDB-310780 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.310780\", \"name\": \"VDB-310780 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.584363\", \"name\": \"Submit #584363 | Linksys RE6500\\u3001RE6250\\u3001RE6300\\u3001RE6350\\u3001RE7000\\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_4/4.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.linksys.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"In Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Es geht um die Funktion setDeviceURL der Datei /goform/setDeviceURL. Durch Manipulieren des Arguments DeviceURL mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk erfolgen. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"OS Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-06-02T10:31:04.552Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2025-5441\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-02T12:10:19.108Z\", \"dateReserved\": \"2025-06-01T17:06:22.538Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-06-02T10:31:04.552Z\", \"assignerShortName\": \"VulDB\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…