CVE-2025-5310 (GCVE-0-2025-5310)
Vulnerability from cvelistv5
Published
2025-06-27 17:22
Modified
2025-06-27 17:41
CWE
Summary
Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-5310",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-27T17:41:36.119969Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-27T17:41:45.800Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX 4",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Plus",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "4.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ProGauge MagLink LX Ultimate",
          "vendor": "Dover Fueling Solutions",
          "versions": [
            {
              "lessThan": "5.20.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Souvik Kandar of Microsec reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions ProGauge MagLink LX Consoles\u0026nbsp;expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution."
            }
          ],
          "value": "Dover Fueling Solutions ProGauge MagLink LX Consoles\u00a0expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-27T17:22:02.680Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-05"
        },
        {
          "url": "https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026CT=1736953471669\u0026id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"\u003ewebsite\u003c/a\u003e.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\n\n\u003cbr\u003e\u003c/p\u003e"
            }
          ],
          "value": "Dover Fueling Solutions recommends users update their ProGauge MagLink \ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx .For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx \u00a0or later."
        }
      ],
      "source": {
        "advisory": "ICSA-25-168-05",
        "discovery": "EXTERNAL"
      },
      "title": "Dover Fueling Solutions ProGauge MagLink LX Consoles Missing Authentication for Critical Function",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-5310",
    "datePublished": "2025-06-27T17:22:02.680Z",
    "dateReserved": "2025-05-28T21:03:37.200Z",
    "dateUpdated": "2025-06-27T17:41:45.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-5310\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2025-06-27T18:15:52.310\",\"lastModified\":\"2025-09-04T03:14:41.530\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dover Fueling Solutions ProGauge MagLink LX Consoles\u00a0expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.\"},{\"lang\":\"es\",\"value\":\"Dover Fueling Solutions ProGauge MagLink LX Consoles exponen una interfaz de framework de comunicaci\u00f3n de destino (TCF) no documentada ni autenticada en un puerto espec\u00edfico. Se pueden crear, eliminar o modificar archivos, lo que podr\u00eda provocar la ejecuci\u00f3n remota de c\u00f3digo.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"references\":[{\"url\":\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026CT=1736953471669\u0026id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-05\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5310\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-27T17:41:36.119969Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-27T17:41:41.030Z\"}}], \"cna\": {\"title\": \"Dover Fueling Solutions ProGauge MagLink LX Consoles Missing Authentication for Critical Function\", \"source\": {\"advisory\": \"ICSA-25-168-05\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Souvik Kandar of Microsec reported this vulnerability to CISA.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 9.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX 4\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX Plus\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Dover Fueling Solutions\", \"product\": \"ProGauge MagLink LX Ultimate\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.20.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Dover Fueling Solutions recommends users update their ProGauge MagLink \\ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \\nmodels. The upgrade can be downloaded from the Dover Fueling Solutions  website https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx .For MagLink LX Ultimate devices, Dover Fueling Solutions recommends users  update to version 5.20.3 https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx \\u00a0or later.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dover Fueling Solutions recommends users update their ProGauge MagLink \\ndevices to Version 4.20.3 or later for MagLink LX 4 and MagLink LX Plus \\nmodels. The upgrade can be downloaded from the Dover Fueling Solutions \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\\\"\u003ewebsite\u003c/a\u003e.\u003cp\u003eFor MagLink LX Ultimate devices, Dover Fueling Solutions recommends users \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026amp;CT=1736953471669\u0026amp;id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026amp;viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026amp;parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\\\"\u003eupdate to version 5.20.3\u003c/a\u003e\u0026nbsp;or later.\\n\\n\u003cbr\u003e\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-168-05\"}, {\"url\": \"https://ociocisa.sharepoint.com/teams/JCDC-ProductionOffice/Shared%20Documents/Forms/AllItems.aspx?OR=Teams%2DHL\u0026CT=1736953471669\u0026id=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017%2FVU%23285756%20%2D%20Dover%20Fueling%20Solutions%20ProGauge%20MAGLINK%20%2D%20Notice%20%28Draft%29%2Ehtml\u0026viewid=243fd1ea%2Da122%2D4cc0%2Dbe91%2Dd0714ca46b87\u0026parent=%2Fteams%2FJCDC%2DProductionOffice%2FShared%20Documents%2FPublications%2FICS%20Publishing%2F2025%20ICSAs%2FJUN%2017\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dover Fueling Solutions ProGauge MagLink LX Consoles\\u00a0expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dover Fueling Solutions ProGauge MagLink LX Consoles\u0026nbsp;expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-06-27T17:22:02.680Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-5310\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-27T17:41:45.800Z\", \"dateReserved\": \"2025-05-28T21:03:37.200Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-06-27T17:22:02.680Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…