CVE-2025-52598 (GCVE-0-2025-52598)
Vulnerability from cvelistv5
Published
2025-12-26 04:07
Modified
2025-12-26 15:15
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-295 - Improper Certificate Validation
Summary
Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has found a flaw that camera's client service does not perform certificate validation. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer's report for details and workarounds.
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hanwha Vision Co., Ltd. | QNV-C8012 |
Version: Prior to version 2.22.05 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-52598",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-26T15:12:31.184142Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-26T15:15:22.694Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QNV-C8012",
"vendor": "Hanwha Vision Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Prior to version 2.22.05"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eCybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has found a flaw that camera\u0027s client service does not perform certificate validation. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer\u0027s report for details and workarounds.\u003c/div\u003e\u003c/div\u003e\n\n\u003cbr\u003e"
}
],
"value": "Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has found a flaw that camera\u0027s client service does not perform certificate validation. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer\u0027s report for details and workarounds."
}
],
"impacts": [
{
"capecId": "CAPEC-22",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-22 Exploiting Trust in Client"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-295",
"description": "CWE-295 Improper Certificate Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-26T04:07:19.958Z",
"orgId": "fc9afe74-3f80-4fb7-a313-e6f036a89882",
"shortName": "Hanwha_Vision"
},
"references": [
{
"url": "https://www.hanwhavision.com/wp-content/uploads/2025/12/Camera-Vulnerability-ReportCVE-2025-5259852601-8075.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insufficient certificate validation",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "fc9afe74-3f80-4fb7-a313-e6f036a89882",
"assignerShortName": "Hanwha_Vision",
"cveId": "CVE-2025-52598",
"datePublished": "2025-12-26T04:07:19.958Z",
"dateReserved": "2025-06-18T07:10:49.610Z",
"dateUpdated": "2025-12-26T15:15:22.694Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-52598\",\"sourceIdentifier\":\"fc9afe74-3f80-4fb7-a313-e6f036a89882\",\"published\":\"2025-12-26T05:16:07.383\",\"lastModified\":\"2025-12-26T05:16:07.383\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has found a flaw that camera\u0027s client service does not perform certificate validation. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer\u0027s report for details and workarounds.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"fc9afe74-3f80-4fb7-a313-e6f036a89882\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"fc9afe74-3f80-4fb7-a313-e6f036a89882\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"references\":[{\"url\":\"https://www.hanwhavision.com/wp-content/uploads/2025/12/Camera-Vulnerability-ReportCVE-2025-5259852601-8075.pdf\",\"source\":\"fc9afe74-3f80-4fb7-a313-e6f036a89882\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-52598\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-26T15:12:31.184142Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-26T15:14:08.715Z\"}}], \"cna\": {\"title\": \"Insufficient certificate validation\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-22\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-22 Exploiting Trust in Client\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 6.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"attackRequirements\": \"PRESENT\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hanwha Vision Co., Ltd.\", \"product\": \"QNV-C8012\", \"versions\": [{\"status\": \"affected\", \"version\": \"Prior to version 2.22.05\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.hanwhavision.com/wp-content/uploads/2025/12/Camera-Vulnerability-ReportCVE-2025-5259852601-8075.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Cybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has found a flaw that camera\u0027s client service does not perform certificate validation. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer\u0027s report for details and workarounds.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cdiv\u003e\u003cdiv\u003eCybersecurity Nozomi Networks Labs, a specialized security company focused on Industrial Control Systems (ICS) and OT/IoT security, has found a flaw that camera\u0027s client service does not perform certificate validation. The manufacturer has released patch firmware for the flaw, please refer to the manufacturer\u0027s report for details and workarounds.\u003c/div\u003e\u003c/div\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-295\", \"description\": \"CWE-295 Improper Certificate Validation\"}]}], \"providerMetadata\": {\"orgId\": \"fc9afe74-3f80-4fb7-a313-e6f036a89882\", \"shortName\": \"Hanwha_Vision\", \"dateUpdated\": \"2025-12-26T04:07:19.958Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-52598\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-26T15:15:22.694Z\", \"dateReserved\": \"2025-06-18T07:10:49.610Z\", \"assignerOrgId\": \"fc9afe74-3f80-4fb7-a313-e6f036a89882\", \"datePublished\": \"2025-12-26T04:07:19.958Z\", \"assignerShortName\": \"Hanwha_Vision\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…