CVE-2025-11120 (GCVE-0-2025-11120)
Vulnerability from cvelistv5
Published
2025-09-28 21:02
Modified
2025-09-29 14:06
CWE
Summary
A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.
Impacted products
Vendor Product Version
Tenda AC8 Version: 16.03.34.06
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11120",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-29T14:06:03.780624Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-29T14:06:07.932Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/alc9700jmo/CVE/issues/19"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC8",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.34.06"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "alc9700 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC8 16.03.34.06 entdeckt. Davon betroffen ist die Funktion formSetServerConfig der Datei /goform/SetServerConfig. Dank Manipulation mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-28T21:02:06.820Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-326201 | Tenda AC8 SetServerConfig formSetServerConfig buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.326201"
        },
        {
          "name": "VDB-326201 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.326201"
        },
        {
          "name": "Submit #664065 | Shenzhen Tenda Technology Co., Ltd. Tenda AC8v4 Router Tenda AC8v4 (V16.03.34.06) Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664065"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/alc9700jmo/CVE/issues/19"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-27T19:52:16.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC8 SetServerConfig formSetServerConfig buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11120",
    "datePublished": "2025-09-28T21:02:06.820Z",
    "dateReserved": "2025-09-27T17:47:12.856Z",
    "dateUpdated": "2025-09-29T14:06:07.932Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-11120\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-09-28T21:15:51.167\",\"lastModified\":\"2025-09-29T19:34:10.030\",\"vulnStatus\":\"Undergoing Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"},{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://github.com/alc9700jmo/CVE/issues/19\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.326201\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.326201\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.664065\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://www.tenda.com.cn/\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://github.com/alc9700jmo/CVE/issues/19\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-11120\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-29T14:06:03.780624Z\"}}}], \"references\": [{\"url\": \"https://github.com/alc9700jmo/CVE/issues/19\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-29T14:05:57.272Z\"}}], \"cna\": {\"title\": \"Tenda AC8 SetServerConfig formSetServerConfig buffer overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"alc9700 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"product\": \"AC8\", \"versions\": [{\"status\": \"affected\", \"version\": \"16.03.34.06\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-09-27T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-09-27T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-09-27T19:52:16.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.326201\", \"name\": \"VDB-326201 | Tenda AC8 SetServerConfig formSetServerConfig buffer overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.326201\", \"name\": \"VDB-326201 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.664065\", \"name\": \"Submit #664065 | Shenzhen Tenda Technology Co., Ltd. Tenda AC8v4 Router Tenda AC8v4 (V16.03.34.06) Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/alc9700jmo/CVE/issues/19\", \"tags\": [\"exploit\", \"issue-tracking\"]}, {\"url\": \"https://www.tenda.com.cn/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Tenda AC8 16.03.34.06 entdeckt. Davon betroffen ist die Funktion formSetServerConfig der Datei /goform/SetServerConfig. Dank Manipulation mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \\u00fcber das Netzwerk erfolgen. Der Exploit wurde der \\u00d6ffentlichkeit bekannt gemacht und k\\u00f6nnte verwendet werden.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-120\", \"description\": \"Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-09-28T21:02:06.820Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-11120\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-29T14:06:07.932Z\", \"dateReserved\": \"2025-09-27T17:47:12.856Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-09-28T21:02:06.820Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…