CVE-2025-10548 (GCVE-0-2025-10548)
Vulnerability from cvelistv5
Published
2025-09-23 06:49
Modified
2025-09-23 19:34
CWE
  • CWE-295 - Improper Certificate Validation
Summary
The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-10548",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-23T19:34:25.010051Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-23T19:34:50.357Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "CleverControl employee monitoring software",
          "vendor": "CleverControl",
          "versions": [
            {
              "status": "affected",
              "version": "11.5.1041.6"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Daniel Hirschberger, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Thorger Jansen, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Tobias Niemann, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Marius Renner, SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using \u003ccode\u003ecurl.exe --insecure\u003c/code\u003e, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\u003c/p\u003e"
            }
          ],
          "value": "The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-558",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-558 Replace Trusted Executable"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-295",
              "description": "CWE-295 Improper Certificate Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-23T06:49:33.659Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/clevercontrol"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
            }
          ],
          "value": "The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-10548",
    "datePublished": "2025-09-23T06:49:33.659Z",
    "dateReserved": "2025-09-16T11:38:55.400Z",
    "dateUpdated": "2025-09-23T19:34:50.357Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-10548\",\"sourceIdentifier\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\",\"published\":\"2025-09-23T07:15:34.957\",\"lastModified\":\"2025-09-24T18:11:24.520\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":2.5}]},\"weaknesses\":[{\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-295\"}]}],\"references\":[{\"url\":\"https://r.sec-consult.com/clevercontrol\",\"source\":\"551230f0-3615-47bd-b7cc-93e92e730bbf\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-10548\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-09-23T19:34:25.010051Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-09-23T19:34:45.469Z\"}}], \"cna\": {\"title\": \"Missing Certificate Validation in CleverControl Installer Allows Remote Code Execution\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Daniel Hirschberger, SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Thorger Jansen, SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Tobias Niemann, SEC Consult Vulnerability Lab\"}, {\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Marius Renner, SEC Consult Vulnerability Lab\"}], \"impacts\": [{\"capecId\": \"CAPEC-558\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-558 Replace Trusted Executable\"}]}], \"affected\": [{\"vendor\": \"CleverControl\", \"product\": \"CleverControl employee monitoring software\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.5.1041.6\"}], \"defaultStatus\": \"unknown\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"The vendor did not respond to any communication attempts. Therefore, no patch is available at the time of publication.\", \"base64\": false}]}], \"references\": [{\"url\": \"https://r.sec-consult.com/clevercontrol\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using curl.exe --insecure, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eThe CleverControl employee monitoring software (v11.5.1041.6) fails to validate TLS server certificates during the installation process. The installer downloads and executes external components using \u003ccode\u003ecurl.exe --insecure\u003c/code\u003e, enabling a man-in-the-middle attacker to deliver malicious files that are executed with SYSTEM privileges. This can lead to full remote code execution with administrative rights. No patch is available as the vendor has been unresponsive. It is assumed that previous versions are also affected, but this is not confirmed.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-295\", \"description\": \"CWE-295 Improper Certificate Validation\"}]}], \"providerMetadata\": {\"orgId\": \"551230f0-3615-47bd-b7cc-93e92e730bbf\", \"shortName\": \"SEC-VLab\", \"dateUpdated\": \"2025-09-23T06:49:33.659Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-10548\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-09-23T19:34:50.357Z\", \"dateReserved\": \"2025-09-16T11:38:55.400Z\", \"assignerOrgId\": \"551230f0-3615-47bd-b7cc-93e92e730bbf\", \"datePublished\": \"2025-09-23T06:49:33.659Z\", \"assignerShortName\": \"SEC-VLab\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.


Loading…