CVE-2025-10150 (GCVE-0-2025-10150)
Vulnerability from cvelistv5
Published
2025-10-28 07:24
Modified
2025-10-28 13:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-833 - Deadlock
Summary
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects
smartLink HW-PN: from 1.02 through 1.03
smartLink HW-DP: 1.31
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Softing Industrial Automation GmbH | smartLink HW-PN |
Version: 1.02 < |
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-10150",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-28T13:27:44.147539Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T13:28:01.850Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "smartLink HW-PN",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.03",
"status": "affected",
"version": "1.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "smartLink HW-DP",
"vendor": "Softing Industrial Automation GmbH",
"versions": [
{
"lessThanOrEqual": "1.31",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.03",
"versionStartIncluding": "1.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*",
"versionEndIncluding": "1.31",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\n\nsmartLink HW-PN: from 1.02 through 1.03\n\nsmartLink HW-DP: 1.31"
}
],
"impacts": [
{
"capecId": "CAPEC-25",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-25 Forced Deadlock"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "AMBER",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-833",
"description": "CWE-833: Deadlock",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-28T07:24:38.296Z",
"orgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"shortName": "Softing"
},
"references": [
{
"tags": [
"x_html"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html"
},
{
"tags": [
"x_json"
],
"url": "https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "This issue is fixed in\n\nsmartLink HW-PN: 1.04\n\nsmartLink HW-DP: 1.32"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Webserver crash caused by scanning on TCP port 80",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "10de8ef9-5c89-4b17-8228-e97b74acf4bd",
"assignerShortName": "Softing",
"cveId": "CVE-2025-10150",
"datePublished": "2025-10-28T07:24:38.296Z",
"dateReserved": "2025-09-09T07:27:03.262Z",
"dateUpdated": "2025-10-28T13:28:01.850Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-10150\",\"sourceIdentifier\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"published\":\"2025-10-28T08:15:32.600\",\"lastModified\":\"2025-10-30T15:05:32.197\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\\n\\nsmartLink HW-PN: from 1.02 through 1.03\\n\\nsmartLink HW-DP: 1.31\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:M/U:Amber\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"LOW\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"YES\",\"Recovery\":\"USER\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"MODERATE\",\"providerUrgency\":\"AMBER\"}}]},\"weaknesses\":[{\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-833\"}]}],\"references\":[{\"url\":\"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html\",\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\"},{\"url\":\"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json\",\"source\":\"10de8ef9-5c89-4b17-8228-e97b74acf4bd\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-10150\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-28T13:27:44.147539Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-28T13:27:56.136Z\"}}], \"cna\": {\"title\": \"Webserver crash caused by scanning on TCP port 80\", \"source\": {\"discovery\": \"INTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-25\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-25 Forced Deadlock\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"USER\", \"baseScore\": 8.7, \"Automatable\": \"YES\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:U/RE:M/U:Amber\", \"providerUrgency\": \"AMBER\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"LOW\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"MODERATE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Softing Industrial Automation GmbH\", \"product\": \"smartLink HW-PN\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.02\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.03\"}], \"defaultStatus\": \"affected\"}, {\"vendor\": \"Softing Industrial Automation GmbH\", \"product\": \"smartLink HW-DP\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.31\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"This issue is fixed in\\n\\nsmartLink HW-PN: 1.04\\n\\nsmartLink HW-DP: 1.32\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eThis issue is fixed in\u003c/p\u003e\u003cp\u003esmartLink HW-PN: 1.04\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.32\u003cbr\u003e\u003c/p\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.html\", \"tags\": [\"x_html\"]}, {\"url\": \"https://industrial.softing.com/fileadmin/psirt/downloads/2025/CVE-2025-10150.json\", \"tags\": [\"x_json\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects\\n\\nsmartLink HW-PN: from 1.02 through 1.03\\n\\nsmartLink HW-DP: 1.31\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.\u003cp\u003eThis issue affects\u003c/p\u003e\u003cp\u003esmartLink HW-PN: from 1.02 through 1.03\u003c/p\u003e\u003cp\u003esmartLink HW-DP: 1.31\u003cbr\u003e\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-833\", \"description\": \"CWE-833: Deadlock\"}]}], \"cpeApplicability\": [{\"nodes\": [{\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-pn:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"1.03\", \"versionStartIncluding\": \"1.02\"}], \"operator\": \"OR\"}, {\"negate\": false, \"cpeMatch\": [{\"criteria\": \"cpe:2.3:a:softing_industrial_automation_gmbh:smartlink_hw-dp:*:*:*:*:*:*:*:*\", \"vulnerable\": true, \"versionEndIncluding\": \"1.31\", \"versionStartIncluding\": \"0\"}], \"operator\": \"OR\"}], \"operator\": \"OR\"}], \"providerMetadata\": {\"orgId\": \"10de8ef9-5c89-4b17-8228-e97b74acf4bd\", \"shortName\": \"Softing\", \"dateUpdated\": \"2025-10-28T07:24:38.296Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-10150\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-28T13:28:01.850Z\", \"dateReserved\": \"2025-09-09T07:27:03.262Z\", \"assignerOrgId\": \"10de8ef9-5c89-4b17-8228-e97b74acf4bd\", \"datePublished\": \"2025-10-28T07:24:38.296Z\", \"assignerShortName\": \"Softing\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.
Loading…
Loading…