GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-9414 (GCVE-0-2024-9414)

Vulnerability from cvelistv5 – Published: 2024-10-17 15:59 – Updated: 2024-10-17 17:52
VLAI
Title
Cross-site Scripting vulnerability in LCDS LAquis SCADA
Summary
In LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-17 17:01 UTC
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-9414",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T17:01:13.734098Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T17:52:13.378Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LAquis SCADA",
          "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
          "versions": [
            {
              "status": "affected",
              "version": "4.7.1.511"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Mounir Aarab reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIn LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions.\u003c/p\u003e\u003cbr\u003e"
            }
          ],
          "value": "In LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-10-17T15:59:24.981Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.611 or newer\u003c/a\u003e\u0026nbsp;versions of LAquis SCADA.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "LCDS recommends users update to  version 4.7.1.611 or newer https://laquisscada.com/ \u00a0versions of LAquis SCADA."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Cross-site Scripting vulnerability in LCDS LAquis SCADA",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-9414",
    "datePublished": "2024-10-17T15:59:24.981Z",
    "dateReserved": "2024-10-01T17:19:35.637Z",
    "dateUpdated": "2024-10-17T17:52:13.378Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-9414",
      "date": "2026-09-20",
      "epss": "0.00651",
      "percentile": "0.4975"
    },
    "fkie_nvd": {
      "descriptions": [
        {
          "lang": "en",
          "value": "In LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions."
        },
        {
          "lang": "es",
          "value": "En la versi\u00f3n 4.7.1.511 de LAquis SCADA, una vulnerabilidad de Cross-Site Scripting podr\u00eda permitir a un atacante inyectar c\u00f3digo arbitrario en una p\u00e1gina web. Esto podr\u00eda permitirle robar cookies, redirigir a los usuarios o realizar acciones no autorizadas."
        }
      ],
      "id": "CVE-2024-9414",
      "lastModified": "2024-10-18T12:52:33.507",
      "metrics": {
        "cvssMetricV40": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackRequirements": "NONE",
              "attackVector": "NETWORK",
              "automatable": "NOT_DEFINED",
              "availabilityRequirements": "NOT_DEFINED",
              "baseScore": 7.0,
              "baseSeverity": "HIGH",
              "confidentialityRequirements": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirements": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
              "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
              "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
              "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
              "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "recovery": "NOT_DEFINED",
              "safety": "NOT_DEFINED",
              "subsequentSystemAvailability": "NONE",
              "subsequentSystemConfidentiality": "NONE",
              "subsequentSystemIntegrity": "NONE",
              "userInteraction": "ACTIVE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnerabilityResponseEffort": "NOT_DEFINED",
              "vulnerableSystemAvailability": "NONE",
              "vulnerableSystemConfidentiality": "HIGH",
              "vulnerableSystemIntegrity": "LOW"
            },
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-10-17T16:15:04.980",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-02"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-79"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "LAquis SCADA",
                "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
                "versions": [
                  {
                    "status": "affected",
                    "version": "4.7.1.511"
                  }
                ]
              }
            ],
            "source": "ics-cert@hq.dhs.gov"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "In LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions."
          },
          {
            "lang": "es",
            "value": "En la versi\u00f3n 4.7.1.511 de LAquis SCADA, una vulnerabilidad de Cross-Site Scripting podr\u00eda permitir a un atacante inyectar c\u00f3digo arbitrario en una p\u00e1gina web. Esto podr\u00eda permitirle robar cookies, redirigir a los usuarios o realizar acciones no autorizadas."
          }
        ],
        "id": "CVE-2024-9414",
        "lastModified": "2026-06-17T08:24:31.717",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.0,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-9414",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T17:01:13.734098Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-10-17T16:15:04.980",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-02"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T22:04:39+00:00",
      "cve": "CVE-2024-9414",
      "id": "CVE-2024-9414",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Cross-site Scripting vulnerability in LCDS LAquis SCADA",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-9414.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-9414",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-17T17:01:13.734098Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-17T17:01:22.611Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "LAquis SCADA",
              "vendor": "LCDS - Le\u00e3o Consultoria e Desenvolvimento de Sistemas Ltda ME",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.7.1.511"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Mounir Aarab reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eIn LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions.\u003c/p\u003e\u003cbr\u003e"
                }
              ],
              "value": "In LAquis SCADA version 4.7.1.511, a cross-site scripting vulnerability could allow an attacker to inject arbitrary code into a web page. This could allow an attacker to steal cookies, redirect users, or perform unauthorized actions."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-17T15:59:24.981Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-291-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.611 or newer\u003c/a\u003e\u0026nbsp;versions of LAquis SCADA.\u003c/p\u003e\u003cbr\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "LCDS recommends users update to  version 4.7.1.611 or newer https://laquisscada.com/ \u00a0versions of LAquis SCADA."
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Cross-site Scripting vulnerability in LCDS LAquis SCADA",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-9414",
        "datePublished": "2024-10-17T15:59:24.981Z",
        "dateReserved": "2024-10-01T17:19:35.637Z",
        "dateUpdated": "2024-10-17T17:52:13.378Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…