cve-2024-46890
Vulnerability from cvelistv5
Published
2024-11-12 12:49
Modified
2024-11-12 14:28
Summary
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:seimens:sinec_ins:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinec_ins",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "V1.0 SP2 Update 3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-46890",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-12T14:26:52.518770Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-12T14:28:21.227Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SINEC INS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0 SP2 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T12:49:41.829Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-915275.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-46890",
    "datePublished": "2024-11-12T12:49:41.829Z",
    "dateReserved": "2024-09-12T11:24:19.243Z",
    "dateUpdated": "2024-11-12T14:28:21.227Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-46890\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-11-12T13:15:09.463\",\"lastModified\":\"2024-11-13T23:12:39.993\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEC INS (All versions \u003c V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEC INS (todas las versiones \u0026lt; V1.0 SP2 Update 3). La aplicaci\u00f3n afectada no valida correctamente la entrada enviada a endpoints espec\u00edficos de su API web. Esto podr\u00eda permitir que un atacante remoto autenticado con privilegios elevados en la aplicaci\u00f3n ejecute c\u00f3digo arbitrario en el sistema operativo subyacente.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.4,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"HIGH\",\"subsequentSystemIntegrity\":\"HIGH\",\"subsequentSystemAvailability\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0\",\"matchCriteriaId\":\"C89891C1-DFD7-4E1F-80A9-7485D86A15B5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"4664B195-AF14-4834-82B3-0B2C98020EB6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"75BC588E-CDF0-404E-AD61-02093A1DF343\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"A334F7B4-7283-4453-BAED-D2E01B7F8A6E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*\",\"matchCriteriaId\":\"A6BEA71C-CA81-4B5D-A688-2B21E62DC351\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B405F22-5517-49F5-A7CA-1E50D58DFC75\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-915275.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.