cve-2024-35522
Vulnerability from cvelistv5
Published
2024-10-11 00:00
Modified
2025-03-13 16:22
Summary
Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.
References
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:h:netgear:ex3700_ac750:*:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "ex3700_ac750",
                  vendor: "netgear",
                  versions: [
                     {
                        lessThan: "1.0.0.98",
                        status: "affected",
                        version: "0",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-35522",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-10-15T14:50:40.670823Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            problemTypes: [
               {
                  descriptions: [
                     {
                        cweId: "CWE-77",
                        description: "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
                        lang: "en",
                        type: "CWE",
                     },
                  ],
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-13T16:22:22.580Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  attackComplexity: "LOW",
                  attackVector: "ADJACENT_NETWORK",
                  availabilityImpact: "HIGH",
                  baseScore: 8.4,
                  baseSeverity: "HIGH",
                  confidentialityImpact: "HIGH",
                  integrityImpact: "HIGH",
                  privilegesRequired: "HIGH",
                  scope: "CHANGED",
                  userInteraction: "NONE",
                  vectorString: "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N",
                  version: "3.1",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-10-11T21:40:13.405Z",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://github.com/consrc/cves/blob/main/CVE-2024-35522.md",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2024-35522",
      datePublished: "2024-10-11T00:00:00.000Z",
      dateReserved: "2024-05-17T00:00:00.000Z",
      dateUpdated: "2025-03-13T16:22:22.580Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      nvd: "{\"cve\":{\"id\":\"CVE-2024-35522\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2024-10-11T22:15:04.117\",\"lastModified\":\"2025-03-13T17:15:32.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.\"},{\"lang\":\"es\",\"value\":\"El extensor de rango WiFi Netgear EX3700 ' AC750 WiFi Essentials Edition anterior a 1.0.0.98 contiene una inyección de comando autenticada en operating_mode.cgi a través del parámetro ap_mode con ap_24g_manual establecido en 1 y ap_24g_manual_sec establecido en NotNone.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.7,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.98\",\"matchCriteriaId\":\"0F3F1FD8-CCF2-48D5-8265-1BE8A63F083C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDAA5899-B73C-4690-853E-B5400F034BE1\"}]}]}],\"references\":[{\"url\":\"https://github.com/consrc/cves/blob/main/CVE-2024-35522.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-35522\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-15T14:50:40.670823Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:netgear:ex3700_ac750:*:*:*:*:*:*:*:*\"], \"vendor\": \"netgear\", \"product\": \"ex3700_ac750\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"1.0.0.98\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-15T14:52:47.931Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 8.4, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://github.com/consrc/cves/blob/main/CVE-2024-35522.md\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Netgear EX3700 ' AC750 WiFi Range Extender Essentials Edition before 1.0.0.98 contains an authenticated command injection in operating_mode.cgi via the ap_mode parameter with ap_24g_manual set to 1 and ap_24g_manual_sec set to NotNone.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2024-10-11T21:40:13.405Z\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2024-35522\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-13T16:22:22.580Z\", \"dateReserved\": \"2024-05-17T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2024-10-11T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.