cve-2024-28973
Vulnerability from cvelistv5
Published
2024-06-26 02:31
Modified
2024-08-02 01:03
Severity ?
EPSS score ?
Summary
Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Stored Cross-Site Scripting Vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the storage of malicious HTML or JavaScript codes in a trusted application data store. When a high privileged victim user accesses the data store through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | PowerProtect DD |
Version: 7.0 ≤ 7.13 Version: N/A ≤ Version: N/A ≤ |
{ containers: { adp: [ { metrics: [ { other: { content: { id: "CVE-2024-28973", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-06-26T13:22:14.553956Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-06-26T13:22:25.495Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, { providerMetadata: { dateUpdated: "2024-08-02T01:03:51.253Z", orgId: "af854a3a-2127-422b-91ae-364da2661108", shortName: "CVE", }, references: [ { tags: [ "vendor-advisory", "x_transferred", ], url: "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities", }, ], title: "CVE Program Container", }, ], cna: { affected: [ { defaultStatus: "unaffected", product: "PowerProtect DD", vendor: "Dell", versions: [ { lessThanOrEqual: "7.13", status: "affected", version: "7.0", versionType: "semver", }, { lessThan: "2.7.7", status: "affected", version: "N/A", versionType: "semver", }, { lessThan: "5.16.0.0", status: "affected", version: "N/A", versionType: "semver", }, ], }, ], datePublic: "2024-06-24T06:30:00.000Z", descriptions: [ { lang: "en", supportingMedia: [ { base64: false, type: "text/html", value: "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Stored Cross-Site Scripting Vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the storage of malicious HTML or JavaScript codes in a trusted application data store. When a high privileged victim user accesses the data store through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery", }, ], value: "Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Stored Cross-Site Scripting Vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the storage of malicious HTML or JavaScript codes in a trusted application data store. When a high privileged victim user accesses the data store through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery", }, ], metrics: [ { cvssV3_1: { attackComplexity: "LOW", attackVector: "NETWORK", availabilityImpact: "LOW", baseScore: 5.9, baseSeverity: "MEDIUM", confidentialityImpact: "LOW", integrityImpact: "LOW", privilegesRequired: "HIGH", scope: "CHANGED", userInteraction: "REQUIRED", vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L", version: "3.1", }, format: "CVSS", scenarios: [ { lang: "en", value: "GENERAL", }, ], }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-79", description: "CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-06-26T02:31:10.767Z", orgId: "c550e75a-17ff-4988-97f0-544cde3820fe", shortName: "dell", }, references: [ { tags: [ "vendor-advisory", ], url: "https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities", }, ], source: { discovery: "UNKNOWN", }, x_generator: { engine: "Vulnogram 0.2.0", }, }, }, cveMetadata: { assignerOrgId: "c550e75a-17ff-4988-97f0-544cde3820fe", assignerShortName: "dell", cveId: "CVE-2024-28973", datePublished: "2024-06-26T02:31:10.767Z", dateReserved: "2024-03-13T15:44:22.627Z", dateUpdated: "2024-08-02T01:03:51.253Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2024-28973\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-06-26T03:15:09.640\",\"lastModified\":\"2025-02-03T14:59:08.020\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Stored Cross-Site Scripting Vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the storage of malicious HTML or JavaScript codes in a trusted application data store. When a high privileged victim user accesses the data store through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery\"},{\"lang\":\"es\",\"value\":\"Dell PowerProtect DD, versiones anteriores a 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contienen una vulnerabilidad de Cross-Site Scripting Almacenado. Un atacante remoto con altos privilegios podría explotar esta vulnerabilidad, lo que llevaría al almacenamiento de códigos HTML o JavaScript maliciosos en un almacén de datos de aplicaciones confiable. Cuando un usuario víctima con altos privilegios accede al almacén de datos a través de sus navegadores, el navegador web ejecuta el código malicioso en el contexto de la aplicación web vulnerable. La explotación puede dar lugar a la divulgación de información, el robo de sesiones o la falsificación de solicitudes por parte del cliente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":1.7,\"impactScore\":3.7},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0\",\"versionEndIncluding\":\"7.13\",\"matchCriteriaId\":\"51B3D8A3-950B-4D4E-9E4D-7D1ADE791C93\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd3300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA4D9616-4482-4173-9507-6B8EC15F3521\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd6400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A81372F-E8DC-49AB-AC12-700F76D4C2C6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd6900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5525030D-2AA9-4AB6-8B15-D09214C1834E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd9400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C08E46D-6795-46DB-BA6C-548D7B8EBFA5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd9410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F820D2BB-4773-4B2F-BC50-9474B44DB8F6\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd9900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"105F8F20-3EB3-49E7-82BE-3A5742EAA51E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dd9910:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84F58819-777E-43C1-B1EA-FFD7CDF79234\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.16.0.0\",\"matchCriteriaId\":\"D655A40E-7358-4E29-BDC6-8CC2E8BA1D63\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:dm5500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B15806F-F6F1-4B26-921C-FE7620B3539F\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", vulnrichment: { containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T01:03:51.253Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-28973\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-26T13:22:14.553956Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-26T13:22:20.528Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 5.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerProtect DD\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.13\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"2.7.7\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"N/A\", \"lessThan\": \"5.16.0.0\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2024-06-24T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000226148/dsa-2024-219-dell-technologies-powerprotect-dd-security-update-for-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Stored Cross-Site Scripting Vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the storage of malicious HTML or JavaScript codes in a trusted application data store. When a high privileged victim user accesses the data store through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerProtect DD, versions prior to 8.0, LTS 7.13.1.0, LTS 7.10.1.30, LTS 7.7.5.40 contain a Stored Cross-Site Scripting Vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to the storage of malicious HTML or JavaScript codes in a trusted application data store. When a high privileged victim user accesses the data store through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application. Exploitation may lead to information disclosure, session theft, or client-side request forgery\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2024-06-26T02:31:10.767Z\"}}}", cveMetadata: "{\"cveId\": \"CVE-2024-28973\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T01:03:51.253Z\", \"dateReserved\": \"2024-03-13T15:44:22.627Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2024-06-26T02:31:10.767Z\", \"assignerShortName\": \"dell\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.